Evidence map›Paper›PMID 30200274›Full record

ArticleSensors (Basel, Switzerland)2018

An Impedimetric Biosensor Based on Ionic Liquid-Modified Graphite Electrodes Developed for microRNA-34a Detection.

Ece Kesici, Ece Eksin, Arzum Erdem

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
0.8field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 24 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Review
  6. Recent Advances in Ionic Liquids in Biomedicine.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2021
    Review
  7. Review
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Ece KesiciAnalytical Chemistry Department, Faculty of Pharmacy, Ege University, Bornova 35100, Turkey. e.kesici93@gmail.com.
Ece EksinAnalytical Chemistry Department, Faculty of Pharmacy, Ege University, Bornova 35100, Turkey. eceksin@hotmail.com.ORCID 0000-0001-7175-2857
Arzum ErdemAnalytical Chemistry Department, Faculty of Pharmacy, Ege University, Bornova 35100, Turkey. arzum.erdem@ege.edu.tr.ORCID 0000-0002-4375-8386
Ege University · TR

Funding

Ege University Scientific Research Project Coordination 18/FBE/003
6 · The paper itself

Abstract

In the present work, an impedimetric nucleic acid biosensor has been designed for the purpose of detection of microRNA (miRNA). Ionic liquid (1-butyl-3-methylimidazolium hexafluorophosphate (IL))-modified chemically activated pencil graphite electrodes (PGEs) were used for the sensitive and selective detection of miRNA-34a. After covalent activation of the PGE surface using covalent agents (CAs), the ionic liquid (IL) was immobilized onto the surface of the chemically activated PGE by passive adsorption. The electrochemical and microscopic characterization of the IL/CA/PGEs was performed by electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and scanning electron microscopy (SEM). DNA probe concentration, miRNA target concentration, and also the hybridization time and wet adsorption time were optimized by using the EIS technique. Then, the hybridization occurred between specific DNA probes and miRNA-34a was immobilized onto the surface of the IL/CA/PGEs. The impedimetric detection of miRNA-DNA hybrid was performed by EIS. The detection limit (DL) was calculated in a linear concentration range of 2⁻10 µg/mL miRNA-34a target, and it was found to be 0.772 µg/mL (109 nM) in phosphate buffer solution (PBS) and 0.826 µg/mL (117 nM) in diluted fetal bovine serum (FBS). The selectivity of impedimetric biosensor for miRNA-34a was also tested against to other non-complementary miRNA sequences both in buffer media, or diluted FBS.

Indexed as

Biosensing TechniquesElectric ImpedanceElectrochemical TechniquesElectrodesGraphiteIonic LiquidsMicroRNAsGraphiteIonic LiquidsMicroRNAselectrochemical impedance spectroscopyfetal bovine serumionic liquidmicroRNAnucleic acid hybridizationpencil graphite electrode

Identifiers

PMID30200274
PMCPMC6164345
OpenAlexW2889104609

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.