ArticleJournal of diabetes science and technology2019
Performance of a Factory-Calibrated, Real-Time Continuous Glucose Monitoring System in Pediatric Participants With Type 1 Diabetes.
Article in Journal of diabetes science and technology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
20 citing papers in PubMed, 1 synthesis or guideline pooled it, 30 citations in OpenAlex.
- Non-invasive and minimally invasive glucose monitoring devices: a systematic review and meta-analysis on diagnostic accuracy of hypoglycaemia detection.Systematic reviews · 2021Pooled it
- Accuracy of a Seventh-Generation Continuous Glucose Monitoring System in Children and Adolescents With Type 1 Diabetes.Journal of diabetes science and technology · 2023Trial
- Thrice daily consumption of a novel, premeal shot containing a low dose of whey protein increases time in euglycemia during 7 days of free-living in individuals with type 2 diabetes.BMJ open diabetes research & care · 2022Trial
- Accuracy of Real Time Continuous Glucose Monitoring during Different Liquid Solution Challenges in Healthy Adults: A Randomized Controlled Cross-Over Trial.Sensors (Basel, Switzerland) · 2022Trial
- Early Dysglycemia Is Detectable Using Continuous Glucose Monitoring in Very Young Children at Risk of Type 1 Diabetes.Diabetes care · 2024Article
- Accuracy of a Real-Time Continuous Glucose Monitor in Pediatric Diabetic Ketoacidosis Admissions.Diabetes technology & therapeutics · 2024Article
- Comparison of Point Accuracy Between Two Widely Used Continuous Glucose Monitoring Systems.Journal of diabetes science and technology · 2024Article
- Accuracy of a Continuous Glucose Monitor During Pediatric Type 1 Diabetes Inpatient Admissions.Diabetes technology & therapeutics · 2024Article
- Evaluating the precision and reliability of real-time continuous glucose monitoring systems in ambulatory settings: a systematic review.Therapeutic advances in endocrinology and metabolism · 2024Review
- Accuracy of continuous glucose monitoring during exercise-related hypoglycemia in individuals with type 1 diabetes.Frontiers in endocrinology · 2024Article
- Performance of real-time continuous glucose monitoring during track and field training in adolescents with type 1 diabetes.Pediatric endocrinology, diabetes, and metabolism · 2024Article
- Clinical Performance Evaluation of Continuous Glucose Monitoring Systems: A Scoping Review and Recommendations for Reporting.Journal of diabetes science and technology · 2023Article
- Technologies for Diabetes Self-Monitoring: A Scoping Review and Assessment Using the REASSURED Criteria.Journal of diabetes science and technology · 2022Article
- Accuracy and Safety of Dexcom G7 Continuous Glucose Monitoring in Adults with Diabetes.Diabetes technology & therapeutics · 2022Article
- Continuous Glucose Monitoring in the Intensive Care Unit Following Total Pancreatectomy with Islet Autotransplantation in Children: Establishing Accuracy of the Dexcom G6 Model.Journal of clinical medicine · 2021Article
- Performance of three different continuous glucose monitoring systems in children with type 1 diabetes during a diabetes summer camp.Pediatric diabetes · 2021Article
- Continuous monitoring of diabetes with an integrated microneedle biosensing device through 3D printing.Microsystems & nanoengineering · 2021Article
- Development of an Error Model for a Factory-Calibrated Continuous Glucose Monitoring Sensor with 10-Day Lifetime.Sensors (Basel, Switzerland) · 2019Article
- One Year Clinical Experience of the First Commercial Hybrid Closed-Loop System.Diabetes care · 2019Observational
- Article
Corrections and comments
- Commented on by
Authors and funding
7 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe perceived value and consistent use of continuous glucose monitoring (CGM) systems depends in part on their accuracy. We assessed the performance of a sixth-generation CGM system (Dexcom G6) in children and adolescents.
methodsForty-nine participants (6-17 years of age, mean ± SD of 13.5 ± 3.3 years), all with type 1 diabetes, enrolled and data were available from 37. Each participant wore 1 sensor for up to 10 days and was asked to undergo an in-clinic visit lasting 6-12 hours for frequent blood glucose (BG) sample testing on one of the sensor wear days. Estimated glucose values (EGVs) from the G6 system were compared with venous BG values measured with a laboratory reference instrument (YSI).
resultsThe overall mean absolute relative difference (MARD) for 1387 EGV-YSI pairs was 7.7%, and the overall percentage of EGVs within 20% or 20 mg/dL of the YSI reference value (for YSI > or ⩽100 mg/dL, respectively, the "%20/20") was 96.2%. The %20/20 was 92.1% on Day 1 and 91.0% on Day 10 of sensor wear. For EGVs <70 mg/dL, 92.6% of the YSI values were within 20 mg/dL and for EGVs >250 mg/dL, 100% of the YSI values were within 20%. Differences between EGVs and YSI values in over 99.9% of the pairs posed no or only slight clinical risk as evaluated by surveillance error grid analysis.
conclusionsThe accuracy of the G6 CGM system in pediatrics may encourage consistent use of the system and contribute to improved glycemic outcomes in this population.