Evidence map›Paper›PMID 30196276›Full record

ArticlePhysics in medicine and biology2018

Quantification of temporal resolution improvement factor in SMART-RECON based time-resolved C-arm Cone beam computed tomography angiography (TR-CBCTA).

John W Garrett, Yinsheng Li, Ke Li, Yijing Wu, Kevin Johnson, Sebastian Schafer, Guang-Hong Chen

Abstract read
In one paragraph

Article in Physics in medicine and biology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

John W GarrettDepartment of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, WI 53705, United States of America.ORCID 0000-0002-8152-736X
Yinsheng LiDepartment of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, WI 53705, United States of America.ORCID 0000-0002-1635-5178
Ke LiDepartment of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, WI 53705, United States of America.
Yijing WuDepartment of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, WI 53705, United States of America.
Kevin JohnsonDepartment of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, WI 53705, United States of America.
Sebastian SchaferSiemens Medical Solutions, USA Inc., Hoffman Estates, IL 60192, United States of America.
Guang-Hong ChenDepartment of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, WI 53705, United States of America.

Funding

One Stop Shop Imaging for Acute Ischemic StrokeTreatmentU01EB021183 · NIBIB · UNIVERSITY OF WISCONSIN-MADISON · PI CHEN, GUANG-HONG · 2015 to 2020
$3.5M
NIBIB NIH HHS U01 EB021183
6 · The paper itself

Abstract

In a recently published paper by Li et al (2018 Phys. Med. Biol. 63 075001), reconstruction parameters were optimized for the so-called synchronized multiArtifact reduction with tomographic reconstruction (SMART-RECON) method to enable time-resolved Cone beam computed tomography angiography (TR-CBCTA) from a single short-scan CBCT data set. However, the paper did not quantitatively address how much temporal resolution can be improved by using the SMART-RECON algorithm in TR-CBCTA. The purpose of this note was to present a method to quantify this temporal resolution improvement factor and to use that method to quantify the improvement in temporal resolution using SMART-RECON and optimized reconstruction parameters. In the method proposed in this note, the potential temporal blurring caused by SMART-RECON was modeled as a convolution between a temporal Gaussian blurring kernel and the ground truth temporal enhancement curve. The width parameter of the resulting Gaussian blurring kernel was used as a surrogate metric for temporal resolution to quantify the achievable temporal resolution for the conventional filtered backprojection (FBP) and SMART-RECON methods. The ratio of the surrogate temporal resolutions for the two reconstruction methods was calculated to quantify the factor of temporal resolution improvement. The quantitative results show that the temporal resolution is improved by a factor of 4.5 using SMART-RECON compared with FBP.

Indexed as

AlgorithmsComputed Tomography AngiographyCone-Beam Computed TomographyHumansImage Processing, Computer-AssistedPhantoms, Imaging

Identifiers

PMID30196276
PMCPMC6758546

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.