Evidence map›Paper›PMID 30192225›Full record

ArticleSICOT-J2018

Biomechanical evaluation of annulus fibrosus repair with scaffold and soft anchors in an ex vivo porcine model.

Kresten Rickers, Michael Bendtsen, Dang Quang Svend Le, Albert Jvan der Veen, Cody Eric Bünger

Abstract read
In one paragraph

Article in SICOT-J, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Comparison of biomechanical studies of disc repair devices based on a systematic review.The spine journal : official journal of the North American Spine Society · 2020
    Pooled it
  2. Article
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Kresten RickersOrthopeadicResearch Laboratory, Aarhus University Hospital, Aarhus, Denmark.
Michael BendtsenOrthopeadicResearch Laboratory, Aarhus University Hospital, Aarhus, Denmark.
Dang Quang Svend LeOrthopeadicResearch Laboratory, Aarhus University Hospital, Aarhus, Denmark.
Albert Jvan der VeenVU University Medical Center, Department of Physics and Medical Technology, Research Institute MOVE, Amsterdam, The Netherlands.
Cody Eric BüngerOrthopeadicResearch Laboratory, Aarhus University Hospital, Aarhus, Denmark.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionAltered biomechanical properties, due to intervertebral disc (IVD) degeneration and missing nucleus fibrosus, could be thought as one of the reasons for the back pain many herniation patients experience after surgery. It has been suggested to repair annulus fibrosus (AF) to restore stability and allow nucleus pulposus (NP) replacement and furthermore prevent reherniation. The aim of this study was to evaluate a new method for closing a defect in AF for use in herniation surgery.

methodsOur repair method combines a polycaprolactone (PCL) scaffold plugging herniation and soft anchors to secure the plug. Ex vivo biomechanical testing was carried out in nine porcine lumbar motion segments. Flexion-extension, lateral bending and rotation were repeated three times: first in healthy specimens, second with a full thickness circular defect applied, and third time with the specimens repaired. Finally push out tests were performed to check whether the plug would remain in.

resultsTests showed that applying a defect to the AF increases the range of motion (ROM), neutral zone (NZ) and neutral zone stiffness (NZS). In flexion/extension it was found significant for ROM, NZ, and NZS. For lateral bending and rotation a significant increase in ROM occurred. After AF repair ROM, NZ and NZS were normalized. All plugs remained in the AF during push out test up until 4000 N, but NP was squeezed out through the pores of the scaffold. DISCUSSION: A defect in the AF changes the biomechanical properties in the motion segment, changes that point to instability. Repairing the defect with a PCL plug and soft anchors brought the biomechanical behavior back to native state. This concept is promising and might be a viable way to repair the IVD after surgery.

Identifiers

PMID30192225
PMCPMC6128169

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.