Evidence map›Paper›PMID 30191573›Full record

ArticleMedical physics2018

Theoretical and experimental analysis of photon counting detector CT for proton stopping power prediction.

Vicki T Taasti, David C Hansen, Gregory J Michalak, Amanda J Deisher, Jon J Kruse, Ludvig P Muren, Jørgen B B Petersen, Cynthia H McCollough

Open access · bronzeAbstract read
In one paragraph

Article in Medical physics, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
0.8field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 22 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
  11. Review
  12. Article
  13. Review
  14. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 2 countries.

Vicki T TaastiDepartment of Medical Physics, Aarhus University Hospital, Aarhus, Denmark.
David C HansenDepartment of Medical Physics, Aarhus University Hospital, Aarhus, Denmark.
Gregory J MichalakDepartment of Radiology, Mayo Clinic, Rochester, MN, USA.
Amanda J DeisherDepartment of Radiation Oncology, Mayo Clinic, Rochester, MN, USA.
Jon J KruseDepartment of Radiation Oncology, Mayo Clinic, Rochester, MN, USA.
Ludvig P MurenDepartment of Medical Physics, Aarhus University Hospital, Aarhus, Denmark.
Jørgen B B PetersenDepartment of Medical Physics, Aarhus University Hospital, Aarhus, Denmark.
Cynthia H McColloughDepartment of Radiology, Mayo Clinic, Rochester, MN, USA.
Aarhus University Hospital · DKMayo Clinic in Arizona · US

Funding

Photon-Counting Spectral CT to Reduce Dose and Detect Early Vascular DiseaseR01EB016966 · NIBIB · MAYO CLINIC ROCHESTER · PI MCCOLLOUGH, CYNTHIA H · 2013 to 2017
$5.1M
EXTRAMURAL RES FACIL IMPROVEMENT PROG: POLYCYSTIC KIDNEY DISEASE, RENAL STUDIES,C06RR018898 · NCRR · MAYO CLINIC · PI BURNETT, JOHN C · 2004 to 2004
$2.3M
Danish Cancer Society R90-A5992NCRR NIH HHS C06 RR018898NIBIB NIH HHS R01 EB016966NIH HHS C06 RR018898NIH HHS R01 EB016966
6 · The paper itself

Abstract

purposePhoton counting detectors (PCDs) are being introduced in advanced x-ray computed tomography (CT) scanners. From a single PCD-CT acquisition, multiple images can be reconstructed, each based on only a part of the original x-ray spectrum. In this study, we investigated whether PCD-CT can be used to estimate stopping power ratios (SPRs) for proton therapy treatment planning, both by comparing to other SPR methods proposed for single energy CT (SECT) and dual energy CT (DECT) as well as to experimental measurements.

methodsA previously developed DECT-based SPR estimation method was adapted to PCD-CT data, by adjusting the estimation equations to allow for more energy spectra. The method was calibrated directly on noisy data to increase the robustness toward image noise. The new PCD SPR estimation method was tested in theoretical calculations as well as in an experimental setup, using both four and two energy bin PCD-CT images, and through comparison to two other SPR methods proposed for SECT and DECT. These two methods were also evaluated on PCD-CT images, full spectrum (one-bin) or two-bin images, respectively. In a theoretical framework, we evaluated the effect of patient-specific tissue variations (density and elemental composition) and image noise on the SPR accuracy; the latter effect was assessed by applying three different noise levels (low, medium, and high noise). SPR estimates derived using real PCD-CT images were compared to experimentally measured SPRs in nine organic tissue samples, including fat, muscle, and bone tissues.

resultsFor the theoretical calculations, the root-mean-square error (RMSE) of the SPR estimation was 0.1% for the new PCD method using both two and four energy bins, compared to 0.2% and 0.7% for the DECT- and SECT-based method, respectively. The PCD method was found to be very robust toward CT image noise, with a RMSE of 2.7% when high noise was added to the CT numbers. Introducing tissue variations, the RMSE only increased to 0.5%; even when adding high image noise to the changed tissues, the RMSE stayed within 3.1%. In the experimental measurements, the RMSE over the nine tissue samples was 0.8% when using two energy bins, and 1.0% for the four-bin images.

conclusionsIn all tested cases, the new PCD method produced similar or better results than the SECT- and DECT-based methods, showing an overall improvement of the SPR accuracy. This study thus demonstrated that PCD-CT scans will be a qualified candidate for SPR estimations.

Indexed as

PhotonsProtonsCalibrationImage Processing, Computer-AssistedModels, TheoreticalSignal-To-Noise RatioTomography, X-Ray ComputedProtonsCT noiseexperimental verificationnoise robustnessphoton counting detector CTproton stopping power ratio

Identifiers

PMID30191573
PMCPMC6234096
OpenAlexW2892162443

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.