ArticleDiabetes therapy : research, treatment and education of diabetes and related disorders2018
Impact of Glucose Measuring Systems and Sample Type on Diagnosis Rates of Diabetes Mellitus.
Article in Diabetes therapy : research, treatment and education of diabetes and related disorders, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 10 citations in OpenAlex.
- Improving the Bias of Comparator Methods in Analytical Performance Assessments Through Recalibration.Journal of diabetes science and technology · 2024Article
- Derivation and validation of a blood biomarker score for 2-day mortality prediction from prehospital care: a multicenter, cohort, EMS-based study.Internal and emergency medicine · 2023Article
- Glucose meters: What's the laboratory reference glucose?Journal of medical biochemistry · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 3 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionThe use of glucose point-of-care testing (POCT) devices for the diagnosis of diabetes mellitus (DM) is an ongoing controversy. In patient management, glucose concentrations are determined by POCT and core laboratory glucose methods, and the values are commonly compared even though the samples collected are different, namely, capillary whole blood and venous plasma. In individual patients it is difficult to distinguish between factors that can influence the results, such as sample type and measuring procedure. In this study, glucose concentrations obtained using POCT and core laboratory instruments were assessed to duplicate typical scenarios experienced in healthcare. Corresponding diagnosis rates of impaired glucose tolerance (IGT) and DM based on fixed, method-independent cutoffs were compared.
methodsGlucose concentration was measured by the 2-h oral glucose tolerance test (OGTT) in samples collected from an inpatient cohort and a cohort from the general population. Two POCT methods, namely, a handheld unit-use glucometer and a small bench-top analyzer with batch reagents, and two core laboratory procedures were used to measure glucose concentrations. The sample types were whole blood and plasma samples collected from venous and capillary blood. The glycated hemoglobin level in whole blood was also determined.
resultsA total of 231 subjects were included in the study. The 2-h OGTT glucose concentrations in the capillary whole blood samples showed a positive bias of 0.8 mmol/L compared to those obtained using core laboratory plasma glucose methods, leading to increased rates of diabetes diagnosis. This bias decreased to 0.2 mmol/L when venous blood was used in the tests. A change in the method used by the core laboratory introduced a negative bias of 0.5 mmol/L and, consequently, a lower diagnosis rates. DISCUSSION AND
conclusionVenous blood samples measured at the point-of-care are the most suitable sample type for the measurement of the glucose concentration in the 2-h OGTT. The investigated unit-use POCT method is suitable for the diagnosis of IGT and DM when venous blood samples are collected. Importantly, changes in measurement procedures can introduce a bias and affect diagnosis rates, thereby emphasizing the need for further harmonization of glucose methods. A plain language summary is available for this article.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.