Evidence map›Paper›PMID 30183783›Full record

ArticlePloS one2018

Dynamic image denoising for voxel-wise quantification with Statistical Parametric Mapping in molecular neuroimaging.

Stergios Tsartsalis, Benjamin B Tournier, Christophe E Graf, Nathalie Ginovart, Vicente Ibáñez, Philippe Millet

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.7field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Quantification of PET infusion studies without true equilibrium: A tissue clearance correction.Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism · 2020
    Article
  4. GABAMolecular imaging and biology · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Stergios TsartsalisDivision of Adult Psychiatry, Geneva University Hospitals, Geneva, Switzerland.ORCID 0000-0002-6565-6313
Benjamin B TournierDivision of Adult Psychiatry, Geneva University Hospitals, Geneva, Switzerland.
Christophe E GrafDivision of Medical Rehabilitation, Geneva University Hospitals, Geneva, Switzerland.
Nathalie GinovartDivision of Adult Psychiatry, Geneva University Hospitals, Geneva, Switzerland.
Vicente IbáñezClinical Neurophysiology Unit, Division of Psychiatric Specialties, Geneva University Hospitals, Geneva, Switzerland.
Philippe MilletDivision of Adult Psychiatry, Geneva University Hospitals, Geneva, Switzerland.
University Hospital of Geneva · CHUniversity of Geneva · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposePET and SPECT voxel kinetics are highly noised. To our knowledge, no study has determined the effect of denoising on the ability to detect differences in binding at the voxel level using Statistical Parametric Mapping (SPM).

methodsIn the present study, groups of subject-images with a 10%- and 20%- difference in binding of [123I]iomazenil (IMZ) were simulated. They were denoised with Factor Analysis (FA). Parametric images of binding potential (BPND) were produced with the simplified reference tissue model (SRTM) and the Logan non-invasive graphical analysis (LNIGA) and analyzed using SPM to detect group differences. FA was also applied to [123I]IMZ and [11C]flumazenil (FMZ) clinical images (n = 4) and the variance of BPND was evaluated.

resultsEstimations from FA-denoised simulated images provided a more favorable bias-precision profile in SRTM and LNIGA quantification. Simulated differences were detected in a higher number of voxels when denoised simulated images were used for voxel-wise estimations, compared to quantification on raw simulated images. Variability of voxel-wise binding estimations on denoised clinical SPECT and PET images was also significantly diminished.

conclusionIn conclusion, noise removal from dynamic brain SPECT and PET images may optimize voxel-wise BPND estimations and detection of biological differences using SPM.

Indexed as

AdultAlgorithmsFlumazenilHumansMaleNeuroimagingPositron Emission Tomography Computed TomographyTomography, Emission-Computed, Single-PhotonYoung AdultFlumazeniliomazenil

Identifiers

PMID30183783
PMCPMC6124809
OpenAlexW2890649098

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.