Comparison of manual and dose reduction modes of a MORITA R100 CBCT.

Dennis Rottke, Julia Dreger, Kunihiko Sawada, Kazuya Honda, Dirk Schulze

Abstract read
In one paragraph

Article in Dento maxillo facial radiology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Dennis Rottke1 Digital Diagnostic Center , Freiburg im Breisgau , Germany.ORCID http://orcid.org/0000-0002-3317-2680
Julia Dreger1 Digital Diagnostic Center , Freiburg im Breisgau , Germany.
Kunihiko Sawada3 Department of Radiology, Nihon University School of Dentistry , Tokyo , Japan.
Kazuya Honda3 Department of Radiology, Nihon University School of Dentistry , Tokyo , Japan.
Dirk Schulze1 Digital Diagnostic Center , Freiburg im Breisgau , Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objective: To compare effective dose differences when acquiring (1) dose reduction mode and (2) manual mode in a MORITA R100 CBCT.

methods: 24 exposure protocols with different technique factors were performed in both the dose reduction mode and the manual mode in a Veraviewepocs 3D R100 cone beam CT device. 48 TLD were placed in a RANDO head phantom at 24 different sites. Effective doses were calculated according to the formalism published in the 103rd ICRP report.

results: Effective doses for the dose reduction mode protocols ranged from 14 to 156 µSv [mean = 57 µSv, standard deviation (SD) = 37 µSv], whereas effective doses for the manual mode protocols ranged from 22 to 267 µSv (mean = 94 µSv, SD = 65 µSv). Thus, across all protocols, the dose reduction mode leads to a drop of the effective dose by 38 % (SD = 6 %).

conclusions: The estimated effective doses are significantly lower if dose reduction protocols are acquired.

Indexed as

Spiral Cone-Beam Computed TomographyThermoluminescent DosimetryCone-Beam Computed TomographyPhantoms, ImagingRadiation Dosage

Identifiers

PMID30182744
PMCPMC6476377

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.