ArticleArchives of orthopaedic and trauma surgery2018
Do patient-specific instruments (PSI) for UKA allow non-expert surgeons to achieve the same saw cut accuracy as expert surgeons?
Article in Archives of orthopaedic and trauma surgery, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Should we abandon the patient-specific instrumentation ship in total knee arthroplasty? Not quite yet!BMC musculoskeletal disorders · 2021Pooled it
- Patient-specific instruments do not show advantage over conventional instruments in unicompartmental knee arthroplasty at 2 year follow-up: a prospective, two-centre, randomised, double-blind, controlled trial.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2022Trial
- Single-use, patient-specific instrumentation technology in knee arthroplasty: a comparative study between standard instrumentation and PSI efficiency system.Musculoskeletal surgery · 2020Trial
- Three dimensional printing in unicompartmental knee arthroplasty: current evidence and future directions.International orthopaedics · 2026Review
- Accuracy of total knee arthroplasty using hospital-based 3D printed patient-specific instrumentation: A radiology research.Journal of orthopaedics · 2025Article
- Article
- Article
- Early outcomes of total hip arthroplasty using point-of-care manufactured patient-specific instruments: a single university hospital's initial experience.BMC surgery · 2023Article
- Three-dimensional-printed patient-specific instrumentation is an accurate tool to reproduce femoral bone tunnels in multiple-ligament knee injuries.International orthopaedics · 2023Article
- [New technologies (robotics, custom-made) in unicondylar knee arthroplasty-pro].Der Orthopade · 2021Review
- Patient-reported outcome after patient-specific unicondylar knee arthroplasty for unicompartmental knee osteoarthritis.BMC musculoskeletal disorders · 2020Article
- Patient-specific instrumentation does not improve tibial component coronal alignment for medial UKA compared to conventional instrumentation.Journal of experimental orthopaedics · 2020Article
- What future in the treatment of osteochondral knee defects?Annals of translational medicine · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionHigh-volume unicompartmental knee arthroplasty (UKA) surgeons have lower revision rates, in part due to improved intra-operative component alignment. This study set out to determine whether PSI might allow non-expert surgeons to achieve the same level of accuracy as expert surgeons. MATERIALS AND
methodsThirty-four surgical trainees with no prior experience of UKA, and four high-volume UKA surgeons were asked to perform the tibial saw cuts for a medial UKA in a sawbone model using both conventional and patient-specific instrumentation (PSI) with the aim of achieving a specified pre-operative plan. Half the participants in each group started with conventional instrumentation, and half with PSI. CT scans of the 76 cut sawbones were then segmented and reliably orientated in space, before saw cut position in the sagittal, coronal and axial planes was measured, and compared to the pre-operative plan.
resultsThe compound error (absolute error in the coronal, sagittal and axial planes combined) for experts using conventional instruments was significantly less than that of the trainees (11.6°±4.0° v 7.7° ±2.3º, p = 0.029). PSI improved trainee accuracy to the same level as experts using conventional instruments (compound error 5.5° ±3.4º v 7.7° ±2.3º, p = 0.396) and patient-specific instruments (compound error 5.5° ±3.4º v 7.3° ±4.1º, p = 0.3). PSI did not improve the accuracy of high-volume surgeons (p = 0.3).
conclusionsIn a sawbone model, PSI allowed inexperienced surgeons to achieve more accurate saw cuts, equivalent to expert surgeons, and thus has the potential to reduce revision rates. The next test will be to determine whether these results can be replicated in a clinical trial.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.