ArticleTranslational vision science & technology2018

Handheld Retinal Oximetry in Healthy Young Adults.

Wouter Vehmeijer, Sveinn Hakon Hardarson, Kelly Jonkman, Leon Aarts, Albert Dahan, Einar Stefánsson, Nicoline Schalij-Delfos

Open access · goldAbstract read
In one paragraph

Article in Translational vision science & technology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.5field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 4 citations in OpenAlex.

  1. Review
  2. Article
  3. Advances in Retinal Oximetry.Translational vision science & technology · 2021
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 2 countries.

Wouter VehmeijerDepartment of Ophthalmology, Leiden University Medical Center, Leiden, The Netherlands.
Sveinn Hakon HardarsonDepartment of Physiology, University of Iceland, Reykjavik, Iceland.
Kelly JonkmanDepartment of Anesthesiology, Leiden University Medical Center, Leiden, The Netherlands.
Leon AartsDepartment of Anesthesiology, Leiden University Medical Center, Leiden, The Netherlands.
Albert DahanDepartment of Anesthesiology, Leiden University Medical Center, Leiden, The Netherlands.
Einar StefánssonDepartment of Ophthalmology, Landspítali, Reykjavik, Iceland.
Nicoline Schalij-DelfosDepartment of Ophthalmology, Leiden University Medical Center, Leiden, The Netherlands.
Leiden University Medical Center · NLNational University Hospital of Iceland · ISUniversity of Iceland · IS

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe objective of this study was to measure the relative retinal oxygen saturation with a prototype, mobile handheld oximeter in upright and supine position and to compare these measurements to the gold standard Oxymap T1 retinal oximeter in upright position. A handheld oximeter is needed for measurements of infants with retinopathy of prematurity as well as acutely injured and bedridden adults.

methodsHealthy volunteers (age 18-35) were recruited at the Leiden University Medical Center. Retinal images were acquired with the handheld oximeter and the Oxymap T1. Both cameras are dual-wavelength oximeters and acquire images with wavelengths of 570 and 600 nm. Retinal oxygen saturation values were determined for both the handheld camera and the Oxymap T1.

resultsTwenty-one subjects (age 25 ± 2 years) were included. In upright position, the oxygen saturation for the arterioles was 92.2% to 4.9% vs. 95.5% ± 4.2% and for the venules 57.9% ± 10.2% vs. 57.7% ± 6.4% for the handheld camera and Oxymap T1, respectively. The oxygen saturation was higher in the arterioles than the venules for both cameras (

conclusionsPerformance of the prototype, mobile handheld oximeter Corimap camera compares well with the Oxymap T1, with a slightly larger standard deviation in oxygen saturation measurements, both in upright and supine patients. TRANSLATION RELEVANCE: To date, to our knowledge, no oximeters are available for handheld use and for measurement in supine position in infants and bedridden adults. Here we tested such an oximeter and show that its performance compares well with that of the gold standard Oxymap T1 in healthy adults.

Indexed as

dual-wavelength oximetryhandheld oximetryretinal oximetry

Identifiers

PMID30174997
PMCPMC6114026
OpenAlexW2888826344

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.