Evidence map›Paper›PMID 30174410›Full record

ArticleClinical ophthalmology (Auckland, N.Z.)2018

Comparison of incision size and intraocular lens performance after implantation with three preloaded systems and one manual delivery system.

Javier Mendicute, Thierry Amzallag, Lixin Wang, Aldo A Martinez

Open access · goldAbstract read
In one paragraph

Article in Clinical ophthalmology (Auckland, N.Z.), 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.3field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 16 citations in OpenAlex.

  1. Article
  2. Observational
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 4 institutions in 5 countries.

Javier MendicuteDepartment of Ophthalmology, Hospital Universitario Donostia, San Sebastián, Spain, mendicutejavier@gmail.com.
Thierry AmzallagDepartment of Ophthalmology, Ophthalmic Institute, North of France, Somain, France.
Lixin WangOphthalmology Unit, Novartis Pharmaceuticals Corporation, Fort Worth, TX, USA.
Aldo A MartinezMedical Affairs, Alcon Laboratories, Inc., Fort Worth, TX, USA.
Alcon (United States) · USBiogipuzkoa Health Research Institute · ESInstitut de France · FRNovartis (Switzerland) · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo compare corneal incision size and intraocular lens (IOL) performance/behavior following implantation with the following delivery systems: system U (UltraSert

settingSix study sites (four in Spain and two in France).

designProspective, multicenter, parallel-group, randomized, subject-masked, postmarket clinical study. MATERIALS AND

methodsSubjects were enrolled based on predetermined inclusion/exclusion criteria. The effectiveness end points compared corneal incision size and enlargement after IOL implantation (day of surgery) among all delivery systems. Exploratory end points included mean enlargement of corneal incision size, rates of trapped trailing haptic, IOL adherence to the plunger tip, nozzle tip splitting, and mean surgically induced astigmatism (SIA) at postoperative visit.

resultsOne hundred and nine subjects participated in the study. The mean corneal incision size following IOL implantation was 2.35±0.019 mm for system U, 2.47±0.016 mm for system T, 2.54±0.019 mm for system S, and 2.49±0.011 mm for the manual system. There were five instances of trapped trailing haptic (all system T group, N=26), one instance of IOL adherence to the plunger tip (system S group, N=26), and six instances of nozzle tip splitting (all system S group, N=26). System U had the least SIA (postoperative Day 1) (SIA Centroid = 0.10 diopters [axis: 83.06°]).

conclusionPreloaded delivery system U supported the completion of surgery with the smallest incision size, the least SIA (postoperative Day 1), and no trapped trailing haptics or nozzle tip splitting compared to two other preloaded systems and one manual system.

Indexed as

corneal incisionintraocular lenspreloaded IOL injectorUltraSert

Identifiers

PMID30174410
PMCPMC6109656
OpenAlexW2888227010

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked