Evidence map›Paper›PMID 30170401›Full record

ReviewMedicine2018

Bone quality, and the combination and penetration of cement-bone interface: A comparative micro-CT study of osteoarthritis and rheumatoid arthritis.

Yuanzheng Song, Fahao Zhu, Feng Lin, Feng Zhang, Shuaigong Zhang

Open access · goldAbstract readComparative StudyReview
In one paragraph

Review in Medicine, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
1.9field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it, 17 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Comparing the effect of tourniquet and tranexamic acid on the tibial cement mantle thickness in total knee arthroplasty.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2022
    Article
  6. Article
  7. Article
  8. Three-Dimensional Micro-Computed Tomography of the Adult Mouse Ovary.Frontiers in cell and developmental biology · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 2 countries.

Yuanzheng SongDepartment of Orthopaedics, Tengzhou Central People's Hospital Affiliated to Jining Medical University, Tengzhou, Shandong Province, China.
Fahao Zhu
Feng Lin
Feng Zhang
Shuaigong Zhang
Jining Medical University · CNCreative Commons · USTengzhou Central People's Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

To compare the microstructure, bone quality, and the combination and penetration of cement-bone interface in tissue specimens from patients with osteoarthritis (OA) and rheumatoid arthritis (RA).A total of 80 femoral condyle tissue specimens from 20 OA patients (40 condyles) and 20 RA patients (40 condyles) who underwent total knee arthroplasty at the Department of Orthopaedics in Tengzhou Central People's Hospital were collected between January 2017 and September 2017. According to the random number table method, 20 specimens from the OA group were defined as group A, and 20 specimens in the RA group were defined as group B. The bone quality parameters were measured by micro-CT. The remaining 20 specimens in the OA group and the remaining 20 specimens in the RA group were defined as group C and group D, the cement-bone interfaces were established by the self-made bone cement compression device, and were analyzed by micro-CT.Micro-CT measurement revealed that the bone volume fraction (BV/TV), trabecular thickness (Tb.Th), and trabecular number (Tb.N) in group A were significantly higher than those in group B (all P < .05). The bone surface/bone volume (BS/BV), structure model index (SMI), trabecular separation (Tb.Sp), and degree of anisotropy (DA) in group A were significantly lower than those in group B (all P < .05). The penetration depth of bone cement in group D was significantly greater than those in group C via x-ray detection.The bone quality of OA patients is better than that of RA patients, but the combination and penetration of cement-bone interface of RA patients are better than that of OA patients. The findings advance our understanding of knee prosthesis and have important clinical implications, but they require validations in future studies with larger sample sizes.

Indexed as

Bone CementsArthritis, RheumatoidArthroplasty, Replacement, KneeBone-Implant InterfaceFemurHumansOsteoarthritisPostoperative PeriodX-Ray MicrotomographyBone Cements

Identifiers

PMID30170401
PMCPMC6392652
OpenAlexW2889071401

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.