Evidence map›Paper›PMID 30168634›Full record

ArticleAngewandte Chemie (International ed. in English)2018

Paper-Based Antibody Detection Devices Using Bioluminescent BRET-Switching Sensor Proteins.

Keisuke Tenda, Benice van Gerven, Remco Arts, Yuki Hiruta, Maarten Merkx, Daniel Citterio

Abstract read
In one paragraph

Article in Angewandte Chemie (International ed. in English), 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 38 papers.

0numbers the graph read from it
0cells of the map it votes in
38citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

38 citing papers in PubMed.

  1. Protein engineering: status report.Protein engineering, design & selection : PEDS · 2026
    Review
  2. Article
  3. Article
  4. De Novo Design of High-Performance Cortisol Luminescent Biosensors.Journal of the American Chemical Society · 2025
    Article
  5. Review
  6. Review
  7. Article
  8. Article
  9. Review
  10. Article
  11. Article
  12. Article
  13. Review
  14. Review
  15. Article
  16. Technologies for Frugal and Sensitive Point-of-Care Immunoassays.Annual review of analytical chemistry (Palo Alto, Calif.) · 2022
    Review
  17. Virus Detection: From State-of-the-Art Laboratories to Smartphone-Based Point-of-Care Testing.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2022
    Review
  18. Programmable Cell-Free Transcriptional Switches for Antibody Detection.Journal of the American Chemical Society · 2022
    Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Keisuke TendaDepartment of Applied Chemistry, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, 223-8522, Yokohama, Japan.
Benice van GervenDepartment of Biomedical Engineering and Institute for Complex Molecular Systems (ICMS), Eindhoven University of Technology, P.O. Box 513, 5600, MB, Eindhoven, The Netherlands.
Remco ArtsDepartment of Biomedical Engineering and Institute for Complex Molecular Systems (ICMS), Eindhoven University of Technology, P.O. Box 513, 5600, MB, Eindhoven, The Netherlands.
Yuki HirutaDepartment of Applied Chemistry, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, 223-8522, Yokohama, Japan.ORCID 0000-0001-7303-4189
Maarten MerkxDepartment of Biomedical Engineering and Institute for Complex Molecular Systems (ICMS), Eindhoven University of Technology, P.O. Box 513, 5600, MB, Eindhoven, The Netherlands.ORCID 0000-0001-9484-3882
Daniel CitterioDepartment of Applied Chemistry, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, 223-8522, Yokohama, Japan.ORCID 0000-0001-7420-045X

Funding

European Research Council 280255European Research Council ERC-2011-StG 280255European Research Council ERC-2013-PoC 632274European Research Council ERC-2016-PoC 755471
6 · The paper itself

Abstract

This work reports on fully integrated "sample-in-signal-out" microfluidic paper-based analytical devices (μPADs) relying on bioluminescence resonance energy transfer (BRET) switches for analyte recognition and colorimetric signal generation. The devices use BRET-based antibody sensing proteins integrated into vertically assembled layers of functionalized paper, and their design enables sample volume-independent and fully reagent-free operation, including on-device blood plasma separation. User operation is limited to the application of a single drop (20-30 μL) of sample (serum, whole blood) and the acquisition of a photograph 20 min after sample introduction, with no requirement for precise pipetting, liquid handling, or analytical equipment except for a camera. Simultaneous detection of three different antibodies (anti-HIV1, anti-HA, and anti-DEN1) in whole blood was achieved. Given its simplicity, this type of device is ideally suited for user-friendly point-of-care testing in low-resource environments.

Indexed as

PaperAnimalsAntibodies, ViralColorimetryEquipment DesignHumansLuminescent MeasurementsMicrofluidic Analytical TechniquesPoint-of-Care SystemsSwineVirus DiseasesAntibodies, Viralantibodiesbioluminescencepaper-based analytical devicespoint-of-care testingwhole-blood analysis

Identifiers

PMID30168634
PMCPMC6282528

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.