Evidence map›Paper›PMID 30152204›Full record

ArticleJournal of biomedical optics2018

Sampling depth of a diffuse reflectance spectroscopy probe for in-vivo physiological quantification of murine subcutaneous tumor allografts.

Gage Greening, Ariel Mundo, Narasimhan Rajaram, Timothy J Muldoon

Abstract read
In one paragraph

Article in Journal of biomedical optics, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Minimally invasiveMethodsX · 2022
    Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Low-cost compact optical spectroscopy and novel spectroscopic algorithm for point-of-care real-time monitoring of nanoparticle delivery in biological tissue models.IEEE journal of selected topics in quantum electronics : a publication of the IEEE Lasers and Electro-optics Society
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Gage GreeningUniversity of Arkansas, Department of Biomedical Engineering, Fayetteville, Arkansas, United States.
Ariel MundoUniversity of Arkansas, Department of Biomedical Engineering, Fayetteville, Arkansas, United States.
Narasimhan RajaramUniversity of Arkansas, Department of Biomedical Engineering, Fayetteville, Arkansas, United States.
Timothy J MuldoonUniversity of Arkansas, Department of Biomedical Engineering, Fayetteville, Arkansas, United States.

Funding

The role of optical biomarkers in endoscopic detection and therapeutic monitoring of gastrointestinal cancerR15CA202662 · NCI · UNIVERSITY OF ARKANSAS AT FAYETTEVILLE · PI MULDOON, TIMOTHY J · 2016 to 2016
$442k
NCI NIH HHS R15 CA202662
6 · The paper itself

Abstract

Diffuse reflectance spectroscopy (DRS) is a probe-based spectral biopsy technique used in cancer studies to quantify tissue reduced scattering (μs') and absorption (μa) coefficients and vary in source-detector separation (SDS) to fine-tune sampling depth. In subcutaneous murine tumor allografts or xenografts, a key design requirement is ensuring that the source light interrogates past the skin layer into the tumor without significantly sacrificing signal-to-noise ratio (target of ≥15  dB). To resolve this requirement, a DRS probe was designed with four SDSs (0.75, 2.00, 3.00, and 4.00 mm) to interrogate increasing tissue volumes between 450 and 900 nm. The goal was to quantify percent errors in extracting μa and μs', and to quantify sampling depth into subcutaneous Balb/c-CT26 colon tumor allografts. Using an optical phantom-based experimental method, lookup-tables were constructed relating μa,μs', diffuse reflectance, and sampling depth. Percent errors were <10  %   and 5% for extracting μa and μs', respectively, for all SDSs. Sampling depth reached up to 1.6 mm at the first Q-band of hemoglobin at 542 nm, the key spectral region for quantifying tissue oxyhemoglobin concentration. This work shows that the DRS probe can accurately extract optical properties and the resultant physiological parameters such as total hemoglobin concentration and tissue oxygen saturation, from sufficient depth within subcutaneous Balb/c-CT26 colon tumor allografts. Methods described here can be generalized for other murine tumor models. Future work will explore the feasibility of the DRS in quantifying volumetric tumor perfusion in response to anticancer therapies.

Indexed as

AllograftsAnimalsCell Line, TumorFemaleHemoglobinsImage Interpretation, Computer-AssistedMiceMice, Inbred BALB CNeoplasms, ExperimentalOptical ImagingOxygenPhantoms, ImagingSkinSpectrum AnalysisHemoglobinsOxygenabsorption–scattering coefficientallograftdiffuse reflectance spectroscopyhemoglobinmurine subcutaneous tumoroptical propertiessampling depthtissue oxygen saturation

Identifiers

PMID30152204
PMCPMC8357195

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.