Evidence map›Paper›PMID 30151857›Full record

ArticleMedical physics2018

Patient-based 4D digital breast phantom for perfusion contrast-enhanced breast CT imaging.

Marco Caballo, Ritse Mann, Ioannis Sechopoulos

Abstract read
In one paragraph

Article in Medical physics, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Marco CaballoDepartment of Radiology and Nuclear Medicine, Radboud University Medical Center, PO Box 9101, 6500 HB, Nijmegen, The Netherlands.
Ritse MannDepartment of Radiology and Nuclear Medicine, Radboud University Medical Center, PO Box 9101, 6500 HB, Nijmegen, The Netherlands.
Ioannis SechopoulosDepartment of Radiology and Nuclear Medicine, Radboud University Medical Center, PO Box 9101, 6500 HB, Nijmegen, The Netherlands.

Funding

Image Quality Improvement and Performance Assessment of Dedicated Breast CTR01CA181171 · NCI · STICHTING RADBOUD UNIVERSITAIR MEDISCH CENTRUM I.O. · PI SECHOPOULOS, IOANNIS · 2015 to 2020
$1.1M
NCI NIH HHS R01 CA181171NCI NIH HHS R01CA181171NIH HHSSusan G. Komen Foundation for the Cure IIR13262248
6 · The paper itself

Abstract

purposeThe purpose of this study was to develop a realistic patient-based 4D digital breast phantom including time-varying contrast enhancement for simulation of dedicated breast CT perfusion imaging.

methodsA 3D static phantom is first created by segmenting a breast CT image from a healthy patient into skin, fibroglandular tissue, adipose tissue, and vasculature. For the creation of abnormal cases, a breast lesion model was developed and can be added to the phantom. After defining the necessary perfusion parameters for each tissue (e.g., arterial input function for vasculature, blood volume and blood flow for the other normal tissues) based on contrast-enhanced dynamic breast MRI data, the corresponding time-enhancement curves are computed for each voxel in the phantom, according to tissue type. These curves are calculated by convolution between the arterial input function and a shifted exponential function. This exponential depends on the perfusion parameters associated with each tissue voxel, and, to incorporate normal biological variability, a uniform random distribution is used to vary the perfusion parameters on a voxel-basis. Finally, a 4D array is produced by sampling the continuous time-enhancement curves at the desired sampling rate. Beside modeling different enhancement dynamics according to the given input perfusion parameters, the phantom also includes the possibility to realistically simulate different spatial enhancement patterns for the breast parenchyma, taking into account the arterial sources supplying the breast. Finally, different patterns of contrast medium uptake can also be simulated for the tumor models (homogeneous and rim enhancement).

resultsAs an example, a typical 4D phantom has dimensions of 426 × 421 × 260 × 559 (x, y, z, t), with a voxel size of 273 μm and a sampling time of 1 s. The characteristics of the tumor model can be modified at will to evaluate perfusion in different types of breast lesions. Results show the expected enhancement of tissues, consistent with the given input parameters. Moreover, the tumor models evaluated in this work show different enhancement dynamics according to the tumor type (defined by different input perfusion parameters), and also present a higher enhancement compared to the other healthy tissues, as expected.

conclusionsThe proposed digital phantom can model the breast tissue perfusion during 4D breast CT image acquisition, displaying the different enhancement dynamics that could be found in a real patient breast. This phantom can be used during the development of dynamic contrast-enhanced dedicated breast CT imaging, for optimization of image acquisition, image reconstruction, and image analysis. This modality could provide functional information of the breast, resulting in detection, diagnosis, and treatment improvements of breast cancer with breast CT.

Indexed as

Phantoms, ImagingSignal-To-Noise RatioBreastBreast NeoplasmsHumansImage Processing, Computer-AssistedPerfusion ImagingTomography, X-Ray Computedbreast cancerbreast CTdigital phantomsdynamic contrast-enhanced imaging

Identifiers

PMID30151857
PMCPMC6181787

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.