ArticleMedical physics2018
Patient-based 4D digital breast phantom for perfusion contrast-enhanced breast CT imaging.
Article in Medical physics, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- Human phantom applicability of 3D-printed polylactic acid for X-ray dose analysis: simulation and measurement studies.Radiological physics and technology · 2025Article
- In-line spectroscopy for iodine quantification in dynamic contrast-enhanced dedicated breast CT.Medical physics · 2025Article
- Radiomics in cone-beam breast CT for the prediction of axillary lymph node metastasis in breast cancer: a multi-center multi-device study.European radiology · 2024Article
- 4D digital anthropomorphic breast phantom for iodinated contrast-enhanced imaging.Journal of medical imaging (Bellingham, Wash.) · 2023Article
- An Anthropomorphic Digital Reference Object (DRO) for Simulation and Analysis of Breast DCE MRI Techniques.Tomography (Ann Arbor, Mich.) · 2022Article
- Dedicated breast CT: state of the art-Part II. Clinical application and future outlook.European radiology · 2022Review
- Towards 4D dedicated breast CT perfusion imaging of cancer: development and validation of computer simulated images.Physics in medicine and biology · 2019Article
- Development of 3D patient-based super-resolution digital breast phantoms using machine learning.Physics in medicine and biology · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
purposeThe purpose of this study was to develop a realistic patient-based 4D digital breast phantom including time-varying contrast enhancement for simulation of dedicated breast CT perfusion imaging.
methodsA 3D static phantom is first created by segmenting a breast CT image from a healthy patient into skin, fibroglandular tissue, adipose tissue, and vasculature. For the creation of abnormal cases, a breast lesion model was developed and can be added to the phantom. After defining the necessary perfusion parameters for each tissue (e.g., arterial input function for vasculature, blood volume and blood flow for the other normal tissues) based on contrast-enhanced dynamic breast MRI data, the corresponding time-enhancement curves are computed for each voxel in the phantom, according to tissue type. These curves are calculated by convolution between the arterial input function and a shifted exponential function. This exponential depends on the perfusion parameters associated with each tissue voxel, and, to incorporate normal biological variability, a uniform random distribution is used to vary the perfusion parameters on a voxel-basis. Finally, a 4D array is produced by sampling the continuous time-enhancement curves at the desired sampling rate. Beside modeling different enhancement dynamics according to the given input perfusion parameters, the phantom also includes the possibility to realistically simulate different spatial enhancement patterns for the breast parenchyma, taking into account the arterial sources supplying the breast. Finally, different patterns of contrast medium uptake can also be simulated for the tumor models (homogeneous and rim enhancement).
resultsAs an example, a typical 4D phantom has dimensions of 426 × 421 × 260 × 559 (x, y, z, t), with a voxel size of 273 μm and a sampling time of 1 s. The characteristics of the tumor model can be modified at will to evaluate perfusion in different types of breast lesions. Results show the expected enhancement of tissues, consistent with the given input parameters. Moreover, the tumor models evaluated in this work show different enhancement dynamics according to the tumor type (defined by different input perfusion parameters), and also present a higher enhancement compared to the other healthy tissues, as expected.
conclusionsThe proposed digital phantom can model the breast tissue perfusion during 4D breast CT image acquisition, displaying the different enhancement dynamics that could be found in a real patient breast. This phantom can be used during the development of dynamic contrast-enhanced dedicated breast CT imaging, for optimization of image acquisition, image reconstruction, and image analysis. This modality could provide functional information of the breast, resulting in detection, diagnosis, and treatment improvements of breast cancer with breast CT.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.