Validation of new transmission detector transmission factors for online dosimetry: an experimental study.

So-Yeon Park, Jong Min Park, Jung-In Kim, Sungyoung Lee, Chang Heon Choi

Abstract readValidation Study
In one paragraph

Article in Radiation oncology (London, England), 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

So-Yeon ParkDepartment of Radiation Oncology, Veterans Health Service Medical Center, Seoul, Republic of Korea.
Jong Min ParkInstitute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea.
Jung-In KimInstitute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea.
Sungyoung LeeBiomedical Research Institute, Seoul National University Hospital, Seoul, Republic of Korea.
Chang Heon ChoiInstitute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea. dm140@naver.com.ORCID http://orcid.org/0000-0003-0449-1372

Funding

National R&D Program for Cancer Control No. 1631200National Research Foundation of Korea No. NRF-2017R1C1B1006636
6 · The paper itself

Abstract

backgroundThe demand for dose verification during treatment has risen with the increasing use of intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) in modern radiation therapy. This study aims to validate the transmission factors of a new transmission detector, the Dolphin online monitoring system (IBA Dosimetry, Schwarzenbruck, Germany), for clinical use.

methodsThe transmission factors of the Dolphin detector were evaluated using 6 MV, 6 flattening filter free (FFF), 10 MV, and 10 FFF clinical beams from a TrueBeam STx linear accelerator system. Two-dimensional (2D) dose distributions were measured through portal dosimetry with and without Dolphin to derive the transmission factors. The measurements were performed using 10 IMRT and 10 VMAT treatment plans. The transmission factors were calculated using a non-negative least squares problem solver for the 2D dose matrix. Normalized plans were generated using the derived transmission factors. Patient-specific quality assurance with normalized plans was performed using portal dosimetry and an ArcCheck detector to verify the transmission factors. The gamma passing rates were calculated for the 2%/2 mm and 1%/1 mm criteria.

resultsThe transmission factors for the 6 MV, 6 FFF, 10 MV, and 10 FFF beams, were 0.878, 0.824, 0.913, and 0.883, respectively. The average dose difference between the original plan without Dolphin and the normalized plan with Dolphin was less than 1.8% for all measurements. The mean passing rates of the gamma evaluation were 98.1 ± 2.1 and 82.9 ± 12.6 for the 2%/2 mm and 1%/1 mm criteria, respectively, for portal dosimetry of the original plan. In the case of the portal dosimetry of the normalized plan, the mean passing rates of the gamma evaluation were 97.2 ± 2.8 and 79.1 ± 14.8 for the 2%/2 mm and 1%/1 mm criteria, respectively.

conclusionsThe Dolphin detector can be used for online dosimetry when valid transmission factors are applied to the clinical plan.

Indexed as

Radiotherapy Planning, Computer-AssistedHumansLeast-Squares AnalysisRadiometryRadiotherapy DosageRadiotherapy, Intensity-ModulatedOnline dosimetryPortal dosimetryTransmission detectorTransmission factors

Identifiers

PMID30143012
PMCPMC6109263

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.