Evidence map›Paper›PMID 30141321›Full record

ArticleAnalytical chemistry2018

Electrochemical DNA-Based Sensors for Molecular Quality Control: Continuous, Real-Time Melamine Detection in Flowing Whole Milk.

Hui Li, Jacob Somerson, Fan Xia, Kevin W Plaxco

Abstract readLetter
In one paragraph

Article in Analytical chemistry, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 26 papers.

0numbers the graph read from it
0cells of the map it votes in
26citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

26 citing papers in PubMed.

  1. Review
  2. Review
  3. Article
  4. MercuryMikrochimica acta · 2024
    Article
  5. Codeposition Enhances the Performance of Electrochemical Aptamer-Based Sensors.Langmuir : the ACS journal of surfaces and colloids · 2024
    Article
  6. On the Rational Design of Cooperative Receptors.Annual review of biophysics · 2023
    Review
  7. Review
  8. Real-Time,ACS sensors · 2022
    Review
  9. Single-Molecule Mechanochemical Sensing.Accounts of chemical research · 2022
    Article
  10. Biomarkers and Detection Platforms for Human Health and Performance Monitoring: A Review.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2022
    Review
  11. Review
  12. Review
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Hui LiEngineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry , China University of Geosciences , Wuhan , Hubei 430074 , China.ORCID 0000-0001-7849-9735
Jacob SomersonInterdepartmental Program in Biomolecular Science and Engineering , University of California Santa Barbara , Santa Barbara , California 93106 , United States.
Fan XiaEngineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry , China University of Geosciences , Wuhan , Hubei 430074 , China.
Kevin W PlaxcoDepartment of Chemistry and Biochemistry , University of California Santa Barbara , Santa Barbara , California 93106 , United States.ORCID 0000-0003-4772-8771

Funding

Bio-electrochemical detectors for in vivo continuous monitoringR01EB022015 · NIBIB · UNIVERSITY OF CALIFORNIA SANTA BARBARA · PI KIPPIN, TOD EDWARD, PLAXCO, KEVIN W · 2017 to 2025
$4.6M
NIBIB NIH HHS R01 EB022015
6 · The paper itself

Abstract

The ability to monitor specific molecules in real-time directly in a flowing sample stream and in a manner that does not adulterate that stream could greatly augment quality control in, for example, food processing and pharmaceutical manufacturing. Because they are continuous, reagentless, and able to work directly in complex samples, electrochemical DNA-based (E-DNA) sensors, a modular and, thus, general sensing platform, are promising candidates to fill this role. In support, we describe here an E-DNA sensor supporting the continuous, real-time measurement of melamine in flowing milk. Using target-driven DNA triplex formation to generate an electrochemical output, the sensor responds to rising and falling melamine concentration in seconds without contaminating the product stream. The continuous, autonomous, real-time operation of sensors such as this could provide unprecedented safety, convenience, and cost-effectiveness relative to the batch processes historically employed in molecular quality control.

Indexed as

Biosensing TechniquesAnimalsDNAElectrochemical TechniquesMilkQuality ControlTriazinesDNAmelamineTriazines

Identifiers

PMID30141321
PMCPMC6555152

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.