Evidence map›Paper›PMID 30140698›Full record

ArticleBioMed research international2018

Reliability and Accuracy of Peri-Interventional Stenosis Grading in Peripheral Artery Disease Using Color-Coded Quantitative Fluoroscopy: A Phantom Study Comparing a Clinical and Scientific Postprocessing Software.

Patrick Ghibes, Sasan Partovi, Gerd Grözinger, Petros Martirosian, Fritz Schick, Konstantin Nikolaou, Dominik Ketelsen, Roland Syha, Ulrich Grosse

Open access · hybridAbstract read
In one paragraph

Article in BioMed research international, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.4field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
  3. Quantitative color-coded digital subtraction neuroangiography for pediatric arteriovenous shunting lesions.Child's nervous system : ChNS : official journal of the International Society for Pediatric Neurosurgery · 2019
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 2 countries.

Patrick GhibesDiagnostic and Interventional Radiology, Eberhard-Karls-University, Tübingen, Germany.
Sasan PartoviDepartment of Radiology, University Hospitals Cleveland Medical Center, Case Western Reserve University, 11100 Euclid Avenue, Cleveland, OH 44106, USA.
Gerd GrözingerDiagnostic and Interventional Radiology, Eberhard-Karls-University, Tübingen, Germany.
Petros MartirosianSection on Experimental Radiology, Eberhard-Karls-University, Tübingen, Germany.
Fritz SchickSection on Experimental Radiology, Eberhard-Karls-University, Tübingen, Germany.
Konstantin NikolaouDiagnostic and Interventional Radiology, Eberhard-Karls-University, Tübingen, Germany.
Dominik KetelsenDiagnostic and Interventional Radiology, Eberhard-Karls-University, Tübingen, Germany.
Roland SyhaDiagnostic and Interventional Radiology, Eberhard-Karls-University, Tübingen, Germany.ORCID 0000-0002-6801-8579
Ulrich GrosseDiagnostic and Interventional Radiology, Eberhard-Karls-University, Tübingen, Germany.ORCID 0000-0002-2366-3128
University of Tübingen · DEUniversity Hospitals of Cleveland · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo assess quantitative stenosis grading by color-coded fluoroscopy using an in vitro pulsatile flow phantom.

methodsThree different stenotic tubes (80%, 60%, and 40% diameter restriction) and a nonstenotic reference tube were compared regarding their different flow behavior by using contrast-enhanced fluoroscopy with a flat-detector system for visualisation purposes. Time-density curves (TDC), area under the curve (AUC), time-to-peak (TTP), and different ROI sizes were analyzed in three independent measurements using two different postprocessing software solutions. In addition, exemplary TDCs of a patient with a high-grade stenosis before and after stent angioplasty were acquired.

resultsColor-coded fluoroscopy enabled depiction of differences in AUC and TDC between high-grade (80%), middle (60%), low-grade (40%), and nonstenotic tubes. The best correlation between high-, middle-, and low-grade stenosis was appreciated in ROIs behind the stenosis. This effect was enhanced by using longer integration times (5s, 7s) and a maximum frame rate of image acquisition for analysis (correlation coefficient rho=0.9284 at 5s). TTP showed no significant differences between high- and low-grade stenosis.

conclusionsVarious clinical studies in the literature already demonstrated reproducible and reliable stenosis grading by analyzing TDCs acquired with color-coded fluoroscopy. In contrast to TTP, AUC values derived in ROIs behind the stenosis proved to be reliable parameters for stenosis grading. However, our results also demonstrate that several factors are able to significantly impact the evaluation of AUC values. More precisely, accuracy of acquired AUC values can be improved by choosing longer integration times, a large ROI size adapted to the vessel diameter, and a higher frame rate of image acquisition.

Indexed as

FluoroscopySoftwareConstriction, PathologicHumansImage Processing, Computer-AssistedPeripheral Arterial DiseaseReproducibility of Results

Identifiers

PMID30140698
PMCPMC6081527
OpenAlexW2883464769

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.