Evidence map›Paper›PMID 30134937›Full record

ArticleItalian journal of pediatrics2018

Continuous glucose monitoring (CGM) in very low birth weight newborns needing parenteral nutrition: validation and glycemic percentiles.

Alessandro Perri, Lucia Giordano, Mirta Corsello, Francesca Priolo, Giovanni Vento, Enrico Zecca, Eloisa Tiberi

Open access · goldAbstract read
In one paragraph

Article in Italian journal of pediatrics, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed, 1 pooled it
2.3field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 1 synthesis or guideline pooled it, 26 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Observational
  4. Observational
  5. Article
  6. Review
  7. Article
  8. Article
  9. Review
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 2 countries.

Alessandro PerriDivision of Neonatology, Department of Pediatrics, University Hospital "A.Gemelli" Catholic University of the Sacred Heart, Rome, Italy. aleperrix@gmail.com.ORCID http://orcid.org/0000-0002-8914-8639
Lucia GiordanoDivision of Neonatology, Department of Pediatrics, University Hospital "A.Gemelli" Catholic University of the Sacred Heart, Rome, Italy.
Mirta CorselloDivision of Neonatology, Department of Pediatrics, University Hospital "A.Gemelli" Catholic University of the Sacred Heart, Rome, Italy.
Francesca PrioloDivision of Neonatology, Department of Pediatrics, University Hospital "A.Gemelli" Catholic University of the Sacred Heart, Rome, Italy.
Giovanni VentoDivision of Neonatology, Department of Pediatrics, University Hospital "A.Gemelli" Catholic University of the Sacred Heart, Rome, Italy.
Enrico ZeccaDivision of Neonatology, Department of Pediatrics, University Hospital "A.Gemelli" Catholic University of the Sacred Heart, Rome, Italy.
Eloisa TiberiDivision of Neonatology, Department of Pediatrics, University Hospital "A.Gemelli" Catholic University of the Sacred Heart, Rome, Italy.
Università Cattolica del Sacro Cuore · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundContinuous glucose monitoring using subcutaneous sensors is useful in the management of glucose control in neonatal intensive care. We evaluated feasibility and reliability of a continuous glucose monitoring system in a population of very low birth weight neonates needing parenteral nutrition. Moreover, we presented percentiles of glycemia of the studied population.

methodsVery low birth weight neonates were enrolled within 24 h from birth. An ENLITE sensor connected to a continuous glucose monitoring system was inserted and maintained for at least 72 h. Data obtained with the continuous glucose monitoring system and with a glucometer were compared. Calibration was performed every 12 h.

resultsTwenty-three patients (9 males) were included. Median gestational age was 28 weeks (range 23-30) and median birth weight was 860 g (range 500-1092). A total of 299 paired glucose values were obtained. Modified Clarke Error Grid criteria for clinical significance were met. 74 and 33 episodes of hypoglycemia and hyperglycemia were detected, respectively. 31,329 values of glycemia were analyzed and the percentiles calculated.

conclusionsThis continuous glucose monitoring system is safe and accurate. It allows increasing the detection of hypo- and hyper-glycaemia episodes and it could be routinely used in the management of glucose infusion in very low birth weight neonates under total parenteral nutrition.

Indexed as

Blood GlucoseCohort StudiesDatabases, FactualFeasibility StudiesFemaleGestational AgeHumansHyperglycemiaHypoglycemiaInfant, NewbornInfant, Very Low Birth WeightIntensive Care Units, NeonatalMaleMonitoring, PhysiologicParenteral NutritionPrognosisBlood GlucoseContinuous glucose monitoring systemGlycemic percentilesNeonatal hyperglycemiaNeonatal hypoglycemiaNeonatal intensive care unitParenteral nutritionPretermVery low birth weight

Identifiers

PMID30134937
PMCPMC6106728
OpenAlexW2888697710

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.