ArticleInternational journal of computer assisted radiology and surgery2018
Real-time microrobot posture recognition via biplane X-ray imaging system for external electromagnetic actuation.
Article in International journal of computer assisted radiology and surgery, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 31 citations in OpenAlex.
- Biorobotic Drug Delivery for Biomedical Applications.Molecules (Basel, Switzerland) · 2024Review
- Magnetic-Controlled Microrobot: Real-Time Detection and Tracking through Deep Learning Approaches.Micromachines · 2024Article
- Magnetic Microrobots for In Vivo Cargo Delivery: A Review.Micromachines · 2024Review
- Medical Imaging Technology for Micro/Nanorobots.Nanomaterials (Basel, Switzerland) · 2023Review
- Medical micro- and nanomotors in the body.Acta pharmaceutica Sinica. B · 2023Review
- Visualization of micro-agents and surroundings by real-time multicolor fluorescence microscopy.Scientific reports · 2022Article
- Evolving from Laboratory Toys towards Life-Savers: Small-Scale Magnetic Robotic Systems with Medical Imaging Modalities.Micromachines · 2021Review
- A Review of Microrobot's System: Towards System Integration for Autonomous Actuation In Vivo.Micromachines · 2021Review
- Medical Micro/Nanorobots in Precision Medicine.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2020Review
- A Tumbling Magnetic Microrobot System for Biomedical Applications.Micromachines · 2020Article
- A wireless tattooing capsule endoscope using external electromagnetic actuation and chemical reaction pressure.PloS one · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 2 institutions in 1 country.
Funding
Abstract
purposeAs a promising intravascular therapeutic approach for autonomous catheterization, especially for thrombosis treatment, a microrobot or robotic catheter driven by an external electromagnetic actuation system has been recently investigated. However, the three-dimensional (3D) real-time position and orientation tracking of the microrobot remains a challenge for precise feedback control in clinical applications owing to the micro-size of the microrobot geometry in vessels, along with bifurcation and vulnerability. Therefore, in this paper, we propose a 3D posture recognition method for the unmanned microrobotic surgery driven by an external electromagnetic actuator system.
methodsWe propose a real-time position and spatial orientation tracking method for a millimeter-sized intravascular object or microrobot using a principal component analysis algorithm and an X-ray reconstruction. The suggested algorithm was implemented to an actual controllable wireless microrobot system composed of a bullet-shaped object, a biplane X-ray imaging device, and an electromagnetic actuation system. Numerical computations and experiments were conducted for the performance verification.
resultsThe experimental results showed a good performance of the implemented system with tracking errors less than 0.4 mm in position and 2° in orientation. The proposed tracking technique accomplished a fast processing time, ~ 0.125 ms/frame, and high-precision recognition of the micro-sized object.
conclusionsSince the suggested method does not require pre-information of the object geometry in the human body for its 3D shape and position recognition, it could be applied to various elliptical shapes of the microrobot system with computation time efficacy and recognition accuracy. Hence, the method can be used for therapeutic millimeter- or micron-sized manipulator recognition in vascular, as well as implanted objects in the human body.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.