Evidence map›Paper›PMID 30128830›Full record

ArticleJournal of gastrointestinal surgery : official journal of the Society for Surgery of the Alimentary Tract2019

EUS-Guided Antegrade Biliary Stenting Using a Novel Fully Covered Metal Stent (with Video).

Masanori Yamada, Takeshi Ogura, Rieko Kamiyama, Akira Miyano, Nobu Nishioka, Tadahiro Yamada, Kazuhide Higuchi

Abstract readVideo-Audio Media
PubMed Publisher
In one paragraph

Article in Journal of gastrointestinal surgery : official journal of the Society for Surgery of the Alimentary Tract, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. EUS-guided antegrade procedures.Endoscopic ultrasound · 2019
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Masanori Yamada2nd Department of Internal Medicine, Osaka Medical College, 2-7 Daigakuchou, Takatsukishi, Osaka, 569-8686, Japan.
Takeshi Ogura2nd Department of Internal Medicine, Osaka Medical College, 2-7 Daigakuchou, Takatsukishi, Osaka, 569-8686, Japan. oguratakeshi0411@yahoo.co.jp.
Rieko Kamiyama2nd Department of Internal Medicine, Osaka Medical College, 2-7 Daigakuchou, Takatsukishi, Osaka, 569-8686, Japan.
Akira Miyano2nd Department of Internal Medicine, Osaka Medical College, 2-7 Daigakuchou, Takatsukishi, Osaka, 569-8686, Japan.
Nobu Nishioka2nd Department of Internal Medicine, Osaka Medical College, 2-7 Daigakuchou, Takatsukishi, Osaka, 569-8686, Japan.
Tadahiro Yamada2nd Department of Internal Medicine, Osaka Medical College, 2-7 Daigakuchou, Takatsukishi, Osaka, 569-8686, Japan.
Kazuhide Higuchi2nd Department of Internal Medicine, Osaka Medical College, 2-7 Daigakuchou, Takatsukishi, Osaka, 569-8686, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundRecently, endoscopic ultrasound (EUS)-guided hepaticogastrostomy (HGS) combined with antegrade stenting (AS) has been reported to be associated with longer stent patency and reduced procedure-related adverse events. In EUS-AS, an uncovered metal stent is usually selected to prevent stent misplacement or dislocation. However, because patient survival has improved with advances in chemotherapy, longer stent patency may be required.

aimThe technical feasibility and safety of EUS-guided transhepatic biliary drainage combined with EUS-AS using a novel covered metal stent were evaluated.

methodsPatients with malignant biliary obstruction leading to obstructive jaundice, in whom standard ERCP had failed or was contraindicated, were enrolled in this study between July 2015 and October 2017. As the control group, patients undergoing EUS-AS using an uncovered metal stent were enrolled between October 2014 and June 2015.

resultsA total of 39 patients were enrolled in this study. Among them, EUS-AS using a covered metal stent was performed in 17 patients and using an uncovered metal stent in the remaining 22 patients. Median stent patency including stent dysfunction and patient death was longer in the covered metal stent group (153 days) compared with that of the uncovered metal stent group (108 days) although there were no significant differences (P = 0.06). In only cases with stent dysfunction was median stent patency of the covered metal stent group significantly longer than that of the uncovered metal stent group (not available vs 150 days, P = 0.02).

conclusionsIn conclusion, EUS-guided transluminal biliary drainage combined with EUS-AS using a covered metal stent may be feasible and safe, although the indications for this procedure should be carefully considered.

Indexed as

StentsAdultAgedAged, 80 and overBiliary Tract Surgical ProceduresCholestasisDrainageEndosonographyFemaleHumansLiverMaleMiddle AgedProsthesis FailureTime FactorsUltrasonography, InterventionalERCPEUSEUS-guided antegrade stentingEUS-guided biliary drainage

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.