ArticleInternational orthopaedics2019
Clinical and radiological analysis of a personalized total knee arthroplasty system design.
Article in International orthopaedics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed.
- Prospective insights into tibial stems, cemented versus uncemented in primary total knee arthroplasty: A dual-energy X-ray absorptiometry study.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2025Trial
- A novel knee implant for total knee arthroplasty meets expectations at 10 years. First long-term follow-up report of clinical outcomes and survivorship.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2026Article
- Minimum ten years follow-up of total knee arthroplasty using morphometric implants in patients with osteoarthritis.International orthopaedics · 2026Article
- Total Knee Arthroplasty and the Evolution of Coronal Alignment: From Mechanical to Personalized Strategies.Journal of personalized medicine · 2025Review
- Survival of primary total knee arthroplasty in a modern anatomic implant with and without a short stem extension.Archives of orthopaedic and trauma surgery · 2025Article
- Robotic-assisted total knee arthroplasty provides better joint line and posterior condylar offset restoration than conventional total knee arthroplasty: a retrospective study of radiological outcomes.Journal of robotic surgery · 2025Article
- Radiological assessment of lower limb torsional deformities: a narrative review.Annals of joint · 2025Review
- The Optimal Variation Range of Posterior Condylar Offset Associated with Positive Clinical Outcomes of Primary Total Knee Arthroplasty: A Retrospective Analysis.Orthopaedic surgery · 2024Article
- Mid-term results of an anatomic total knee replacement design.Archives of orthopaedic and trauma surgery · 2024Article
- Tibial implant design in primary TKA: retrospective comparison of two designs for the occurrence of radiolucent lines and aseptic loosening.Archives of orthopaedic and trauma surgery · 2024Article
- Midterm results of a new personalized knee implant for total knee arthroplasty: implant survivorship and patient-reported outcome after five years' follow-up.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2022Article
- Does the anatomic design of total knee prosthesis allow for a better component fit than its nonanatomic predecessor? A matched cohort Study.Arthroplasty today · 2021Article
- Methods of intra- and post-operative determination of the position of the tibial component during total knee replacement.International orthopaedics · 2020Review
- Total knee arthroplasty in Italy: reflections from the last fifteen years and projections for the next thirty.International orthopaedics · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThe objectives of this study were to determine the radiological outcome of a new personalized total knee arthroplasty (TKA) design and also to analyze the radiological reproducibility of the surgical technique. PATIENTS AND
methodsA total of 100 consecutive TKAs performed in 99 patients using Persona knee system were recruited. Weight-bearing standing anteroposterior and lateral radiographs were done in all the patients, both pre-operatively as well as post-operatively, and various radiological parameters were analyzed and compared.
resultsThe full correction of the limb mechanical axis was achieved in 97% of patients, and the radiological parameters of coronal and sagittal alignment of femoral and tibial components showed good results. There were no substantial differences between the mean pre-operative and post-operative patellar height indices, and data were in the normal range. Posterior condylar offset (PCO) and posterior condylar offset ratio (PCOR) had increased as expected after TKA. The coverage of tibia was optimal with data in the normal range.
conclusionsRadiological assessment of the new personalized knee system design showed excellent results with various parameters restored to the normal values. Therefore, the prosthesis can be considered anatomic, and the surgical technique is reproducible allowing the prosthesis to be implanted easily and with high precision.
Indexed as
Identifiers
30128671What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.