Evidence map›Paper›PMID 30127681›Full record

ArticleReports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology

Intrafraction esophageal motion in patients with clinical T1N0 esophageal cancer.

Shuhei Sekii, Yoshinori Ito, Ken Harada, Mayuka Kitaguchi, Kana Takahashi, Koji Inaba, Naoya Murakami, Hiroshi Igaki, Ryohei Sasaki, Jun Itami

Abstract read
In one paragraph

Article in Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Cardiotoxicity of radiation therapy in esophageal cancer.Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Shuhei SekiiDepartment of Radiation Oncology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo 104-0045, Japan.
Yoshinori ItoDepartment of Radiation Oncology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo 104-0045, Japan.
Ken HaradaDepartment of Radiation Oncology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo 104-0045, Japan.
Mayuka KitaguchiDepartment of Radiation Oncology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo 104-0045, Japan.
Kana TakahashiDepartment of Radiation Oncology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo 104-0045, Japan.
Koji InabaDepartment of Radiation Oncology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo 104-0045, Japan.
Naoya MurakamiDepartment of Radiation Oncology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo 104-0045, Japan.
Hiroshi IgakiDepartment of Radiation Oncology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo 104-0045, Japan.
Ryohei SasakiDivision of Radiation Oncology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe-city, Hyogo, Japan.
Jun ItamiDepartment of Radiation Oncology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo 104-0045, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimTo investigate the intrafraction movement of the esophagus using fiducial markers.

backgroundStudies on intrafraction esophageal motion using the fiducial markers are scarce. MATERIALS AND

methodsWe retrospectively analyzed patients with clinical T1N0 esophageal cancer who had received fiducial markers at our hospital between July 2007 and December 2013. Real-Time Position Management System to track the patient's respiration was used, and each patient underwent three-dimensional computed tomography of the resting expiratory and inspiratory level. We used the center of the marker to calculate the distance between the expiratory and inspiratory breath-holds, which were measured with the radiotherapy treatment planning system in three directions: left-right (LR), superior-inferior (SI), and anterior-posterior (AP). The movements at each site were compared with the Kruskal-Wallis analysis and Wilcoxon rank sum test with a Bonferroni correction.

resultsA total of 101 patients with 201 fiducial markers were included. The upper, middle and lower thoracic positions had 40, 77, and 84 markers, respectively. The mean absolute magnitudes of the shifts (standard deviation) were 0.18 (0.19) cm, 0.68 (0.46) cm, and 0.24 (0.24) cm in the LR, SI, and AP directions, respectively. From the cumulative frequency distribution, we assumed that 0.35 cm LR, 0.8 cm SI, and 0.3 cm AP in the upper; 0.5 cm LR, 1.55 cm SI, and 0.55 cm AP in the middle; and 0.75 cm LR, 1.9 cm SI, and 0.95 cm AP in the lower thoracic esophagus covered 95% of the cases.

conclusionsThe internal margin based on the site of esophagus was estimated.

Indexed as

Esophageal cancerFiducial markerGastrointestinal cancerIntrafraction motion

Identifiers

PMID30127681
PMCPMC6097394

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked