Evidence map›Paper›PMID 30125048›Full record

SynthesisThe Cochrane database of systematic reviews2018

Mechanical versus manual chest compressions for cardiac arrest.

Peter L Wang, Steven C Brooks

Abstract readSystematic Review
In one paragraph

Synthesis in The Cochrane database of systematic reviews, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 57 papers, 4 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
57citing papers in PubMed, 4 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

57 citing papers in PubMed, 4 syntheses or guidelines pooled it.

  1. Guideline
  2. Pooled it
  3. Pooled it
  4. Guideline
  5. Trial
  6. Observational
  7. Observational
  8. Mechanical and manual cardiopulmonary resuscitation in traumatic cardiac arrest: a retrospective observational study.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2026
    Observational
  9. Article
  10. Article
  11. Observational
  12. Article
  13. Observational
  14. Article
  15. Article
  16. Article
  17. Observational
  18. Article
  19. Article
  20. Observational
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

2 authors.

Peter L WangDepartment of Medicine, Queen's University, Kingston, Canada.
Steven C Brooks

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMechanical chest compression devices have been proposed to improve the effectiveness of cardiopulmonary resuscitation (CPR).

objectivesTo assess the effectiveness of resuscitation strategies using mechanical chest compressions versus resuscitation strategies using standard manual chest compressions with respect to neurologically intact survival in patients who suffer cardiac arrest. SEARCH

methodsOn 19 August 2017 we searched the Cochrane Central Register of Controlled Studies (CENTRAL), MEDLINE, Embase, Science Citation Index-Expanded (SCI-EXPANDED) and Conference Proceedings Citation Index-Science databases. Biotechnology and Bioengineering Abstracts and Science Citation abstracts had been searched up to November 2009 for prior versions of this review. We also searched two clinical trials registries for any ongoing trials not captured by our search of databases containing published works: Clinicaltrials.gov (August 2017) and the World Health Organization International Clinical Trials Registry Platform portal (January 2018). We applied no language restrictions. We contacted experts in the field of mechanical chest compression devices and manufacturers. SELECTION CRITERIA: We included randomised controlled trials (RCTs), cluster-RCTs and quasi-randomised studies comparing mechanical chest compressions versus manual chest compressions during CPR for patients with cardiac arrest. DATA COLLECTION AND ANALYSIS: We used standard methodological procedures expected by Cochrane. MAIN

resultsWe included five new studies in this update. In total, we included 11 trials in the review, including data from 12,944 adult participants, who suffered either out-of-hospital cardiac arrest (OHCA) or in-hospital cardiac arrest (IHCA). We excluded studies explicitly including patients with cardiac arrest caused by trauma, drowning, hypothermia and toxic substances. These conditions are routinely excluded from cardiac arrest intervention studies because they have a different underlying pathophysiology, require a variety of interventions specific to the underlying condition and are known to have a prognosis different from that of cardiac arrest with no obvious cause. The exclusions were meant to reduce heterogeneity in the population while maintaining generalisability to most patients with sudden cardiac death.The overall quality of evidence for the outcomes of included studies was moderate to low due to considerable risk of bias. Three studies (N = 7587) reported on the designated primary outcome of survival to hospital discharge with good neurologic function (defined as a Cerebral Performance Category (CPC) score of one or two), which had moderate quality evidence. One study showed no difference with mechanical chest compressions (risk ratio (RR) 1.07, 95% confidence interval (CI) 0.82 to 1.39), one study demonstrated equivalence (RR 0.79, 95% CI 0.60 to 1.04), and one study demonstrated reduced survival (RR 0.41, CI 0.21 to 0.79). Two other secondary outcomes, survival to hospital admission (N = 7224) and survival to hospital discharge (N = 8067), also had moderate quality level of evidence. No studies reported a difference in survival to hospital admission. For survival to hospital discharge, two studies showed benefit, four studies showed no difference, and one study showed harm associated with mechanical compressions. No studies demonstrated a difference in adverse events or injury patterns between comparison groups but the quality of data was low. Marked clinical and statistical heterogeneity between studies precluded any pooled estimates of effect. AUTHORS'

conclusionsThe evidence does not suggest that CPR protocols involving mechanical chest compression devices are superior to conventional therapy involving manual chest compressions only. We conclude on the balance of evidence that mechanical chest compression devices used by trained individuals are a reasonable alternative to manual chest compressions in settings where consistent, high-quality manual chest compressions are not possible or dangerous for the provider (eg, limited rescuers available, prolonged CPR, during hypothermic cardiac arrest, in a moving ambulance, in the angiography suite, during preparation for extracorporeal CPR [ECPR], etc.). Systems choosing to incorporate mechanical chest compression devices should be closely monitored because some data identified in this review suggested harm. Special attention should be paid to minimising time without compressions and delays to defibrillation during device deployment.

Indexed as

Blood CirculationCardiopulmonary ResuscitationHeart ArrestHeart MassageHospitalizationHumansPatient DischargeRandomized Controlled Trials as Topic

Identifiers

PMID30125048
PMCPMC6953326

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.