ArticleJournal of neural engineering2018
A novel re-attachable stereotactic frame for MRI-guided neuronavigation and its validation in a large animal and human cadaver model.
Article in Journal of neural engineering, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04283812 (A Re-attachable Stereotactic Frame System for Clinical Interventive Neurosurgery), which is not on this map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
A Re-attachable Stereotactic Frame System for Clinical Interventive Neurosurgery
Who cites it
7 citing papers in PubMed, 13 citations in OpenAlex.
- Utility of a freehand frameless navigation system in computed tomography-assisted ventral bulla osteotomy for otitis media in calves.PloS one · 2026Article
- Pioneering semi-rigid stability: navigating the female pelvis for enhanced precision in binocular vision guidance.Frontiers in surgery · 2026Article
- Expansion of stereotactic work envelope using transformation matrices and geometric algebra for neurosurgery.Biomedical engineering letters · 2025Article
- Basis for error in stereotactic and computer-assisted surgery in neurosurgical applications: literature review.Neurosurgical review · 2022Review
- Orientation-selective and directional deep brain stimulation in swine assessed by functional MRI at 3T.NeuroImage · 2021Article
- DeepNavNet: Automated Landmark Localization for Neuronavigation.Frontiers in neuroscience · 2021Article
- A compact stereotactic system for image-guided surgical intervention.Journal of neural engineering · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors at 4 institutions in 2 countries.
Funding
Abstract
objectiveStereotactic frame systems are the gold-standard for stereotactic surgeries, such as implantation of deep brain stimulation (DBS) devices for treatment of medically resistant neurologic and psychiatric disorders. However, frame-based systems require that the patient is awake with a stereotactic frame affixed to their head for the duration of the surgical planning and implantation of the DBS electrodes. While frameless systems are increasingly available, a reusable re-attachable frame system provides unique benefits. As such, we created a novel reusable MRI-compatible stereotactic frame system that maintains clinical accuracy through the detachment and reattachment of its stereotactic devices used for MRI-guided neuronavigation. APPROACH: We designed a reusable arc-centered frame system that includes MRI-compatible anchoring skull screws for detachment and re-attachment of its stereotactic devices. We validated the stability and accuracy of our system through phantom, in vivo mock-human porcine DBS-model and human cadaver testing. MAIN
resultsPhantom testing achieved a root mean square error (RMSE) of 0.94 ± 0.23 mm between the ground truth and the frame-targeted coordinates; and achieved an RMSE of 1.11 ± 0.40 mm and 1.33 ± 0.38 mm between the ground truth and the CT- and MRI-targeted coordinates, respectively. In vivo and cadaver testing achieved a combined 3D Euclidean localization error of 1.85 ± 0.36 mm (p < 0.03) between the pre-operative MRI-guided placement and the post-operative CT-guided confirmation of the DBS electrode. SIGNIFICANCE: Our system demonstrated consistent clinical accuracy that is comparable to conventional frame and frameless stereotactic systems. Our frame system is the first to demonstrate accurate relocation of stereotactic frame devices during in vivo MRI-guided DBS surgical procedures. As such, this reusable and re-attachable MRI-compatible system is expected to enable more complex, chronic neuromodulation experiments, and lead to a clinically available re-attachable frame that is expected to decrease patient discomfort and costs of DBS surgery.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.