Evidence map›Paper›PMID 30114216›Full record

ArticlePloS one2018

Arterial compliance probe for cuffless evaluation of carotid pulse pressure.

Jayaraj Joseph, Nabeel P M, Malay Ilesh Shah, Mohanasankar Sivaprakasam

Abstract readEvaluation Study
In one paragraph

Article in PloS one, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Observational
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Assessment of Carotid Arterial Stiffness in Community Settings With ARTSENS®.IEEE journal of translational engineering in health and medicine · 2021
    Article
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Jayaraj JosephHealthcare Technology Innovation Centre, Indian Institute of Technology Madras, Chennai, Tamil Nadu, India.
Nabeel P MDepartment of Electrical Engineering, Indian Institute of Technology Madras, Chennai, Tamil Nadu, India.ORCID 0000-0001-7280-0048
Malay Ilesh ShahHealthcare Technology Innovation Centre, Indian Institute of Technology Madras, Chennai, Tamil Nadu, India.ORCID 0000-0003-4296-9322
Mohanasankar SivaprakasamHealthcare Technology Innovation Centre, Indian Institute of Technology Madras, Chennai, Tamil Nadu, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveAssessment of local arterial properties has become increasingly important in cardiovascular research as well as in clinical domains. Vascular wall stiffness indices are related to local pulse pressure (ΔP) level, mechanical and geometrical characteristics of the arterial vessel. Non-invasive evaluation of local ΔP from the central arteries (aorta and carotid) is not straightforward in a non-specialist clinical setting. In this work, we present a method and system for real-time and beat-by-beat evaluation of local ΔP from superficial arteries-a non-invasive, cuffless and calibration-free technique.

methodsThe proposed technique uses a bi-modal arterial compliance probe which consisted of two identical magnetic plethysmograph (MPG) sensors located at 23 mm distance apart and a single-element ultrasound transducer. Simultaneously measured local pulse wave velocity (PWV) and arterial dimensions were used in a mathematical model for calibration-free evaluation of local ΔP. The proposed approach was initially verified using an arterial flow phantom, with invasive pressure catheter as the reference device. The developed porotype device was validated on 22 normotensive human subjects (age = 24.5 ± 4 years). Two independent measurements of local ΔP from the carotid artery were made during physically relaxed and post-exercise condition.

resultsPhantom-based verification study yielded a correlation coefficient (r) of 0.93 (p < 0.001) for estimated ΔP versus reference brachial ΔP, with a non-significant bias and standard deviation of error equal to 1.11 mmHg and ±1.97 mmHg respectively. The ability of the developed system to acquire high-fidelity waveforms (dual MPG signals and ultrasound echoes from proximal and distal arterial walls) from the carotid artery was demonstrated by the in-vivo validation study. The group average beat-to-beat variation in measured carotid local PWV, arterial diameter parameters-distension and end-diastolic diameter, and local ΔP were 4.2%, 2.6%, 3.3%, and 10.2% respectively in physically relaxed condition. Consistent with the physiological phenomenon, local ΔP measured from the carotid artery of young populations was, on an average, 22 mmHg lower than the reference ΔP obtained from the brachial artery. Like the reference brachial blood pressure (BP) monitor, the developed prototype device reliably captured variations in carotid local ΔP induced by an external intervention.

conclusionThis technique could provide a direct measurement of local PWV, arterial dimensions, and a calibration-free estimate of beat-by-beat local ΔP. It can be potentially extended for calibration-free cuffless BP measurement and non-invasive characterization of central arteries with locally estimated biomechanical properties.

Indexed as

Blood PressureAdultBlood Pressure DeterminationCarotid ArteriesEquipment DesignFemaleHumansMalePhantoms, ImagingPlethysmographyPulse Wave AnalysisSensitivity and SpecificityYoung Adult

Identifiers

PMID30114216
PMCPMC6095577

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.