ArticlePhotoacoustics2018
All-optical dual photoacoustic and optical coherence tomography intravascular probe.
Article in Photoacoustics, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
20 citing papers in PubMed, 34 citations in OpenAlex.
- From lab design to clinical translation: photoacoustic endoscopy.Photoacoustics · 2026Review
- Compact photoacoustic endoscopy by measuring initial photoacoustic pressure using phase-shift interferometry.Photoacoustics · 2025Article
- Review
- Perspectives on endoscopic functional photoacoustic microscopy.Applied physics letters · 2024Article
- Scaling down the dimensions of a Fabry-Perot polymer film acoustic sensor for photoacoustic endoscopy.Journal of biomedical optics · 2024Article
- Full-optical photoacoustic imaging using speckle analysis and resolution enhancement by orthogonal pump patterns projection.Scientific reports · 2023Article
- Bend-insensitive fiber optic ultrasonic tracking probe for cardiovascular interventions.Medical physics · 2023Article
- Optical-resolution functional gastrointestinal photoacoustic endoscopy based on optical heterodyne detection of ultrasound.Nature communications · 2022Article
- Silicon-photonics focused ultrasound detector for minimally invasive optoacoustic imaging.Biomedical optics express · 2022Article
- Photoacoustic/Ultrasound Endoscopic Imaging Reconstruction Algorithm Based on the Approximate Gaussian Acoustic Field.Biosensors · 2022Article
- Video-rate dual-modal photoacoustic and fluorescence imaging through a multimode fibre towards forward-viewing endomicroscopy.Photoacoustics · 2022Article
- Enhanced medical diagnosis for dOCTors: a perspective of optical coherence tomography.Journal of biomedical optics · 2021Review
- Advances in Endoscopic Photoacoustic Imaging.Photonics · 2021Article
- Lead halide perovskite for efficient optoacoustic conversion and application toward high-resolution ultrasound imaging.Nature communications · 2021Article
- In-vivo mechanical characterization of coronary atherosclerotic plaques in living swine using intravascular laser speckle imaging.Biomedical optics express · 2021Article
- Multi-spectral intravascular photoacoustic/ultrasound/optical coherence tomography tri-modality system with a fully-integrated 0.9-mm full field-of-view catheter for plaque vulnerability imaging.Biomedical optics express · 2021Article
- Photoacoustic imaging with fiber optic technology: A review.Photoacoustics · 2020Review
- Minimally invasive photoacoustic imaging: Current status and future perspectives.Photoacoustics · 2019Review
- PMN-PT/Epoxy 1-3 composite based ultrasonic transducer for dual-modality photoacoustic and ultrasound endoscopy.Photoacoustics · 2019Article
- Cardiovascular optoacoustics: From mice to men - A review.Photoacoustics · 2019Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 4 institutions in 1 country.
Funding
Abstract
Intravascular imaging in percutaneous coronary interventions can be an invaluable tool in the treatment of coronary artery disease. It is of significant interest to provide molecular imaging contrast that is complementary to structural contrast provided by optical coherence tomography (OCT) and intravascular ultrasound imaging (IVUS). In this study, we developed a dual-modality intravascular imaging probe comprising a commercial OCT catheter and a high sensitivity fiber optic ultrasound sensor, to provide both photoacoustic (PA) and OCT imaging. With PA imaging, the lateral resolution varied from 18 μm to 40 μm; the axial resolution was consistently in the vicinity of 45 μm. We demonstrated the clinical potential of the probe with 2-D circumferential PA and OCT imaging, and with multispectral PA imaging.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.