Evidence map›Paper›PMID 30109701›Full record

SynthesisThe Cochrane database of systematic reviews2018

Transabdominal ultrasound and endoscopic ultrasound for diagnosis of gallbladder polyps.

Sarah Z Wennmacker, Mark P Lamberts, Marcello Di Martino, Joost Ph Drenth, Kurinchi Selvan Gurusamy, Cornelis Jhm van Laarhoven

Abstract readMeta-AnalysisSystematic Review
In one paragraph

Synthesis in The Cochrane database of systematic reviews, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 34 papers, 3 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
34citing papers in PubMed, 3 pooled it
8.3field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

34 citing papers in PubMed, 3 syntheses or guidelines pooled it, 85 citations in OpenAlex.

  1. Guideline
  2. Pooled it
  3. Pooled it
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Review
  16. [Recent Updates on Management and Follow-up of Gallbladder Polyps].The Korean journal of gastroenterology = Taehan Sohwagi Hakhoe chi · 2023
    Review
  17. Article
  18. Article
  19. Gallbladder polyps and adenomyomatosis.The British journal of radiology · 2023
    Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 2 countries.

Sarah Z WennmackerDepartment of Surgery, Radboud University Medical Center Nijmegen, PO Box 9101, internal code 618, Nijmegen, Netherlands, 6500 HB.
Mark P Lamberts
Marcello Di Martino
Joost Ph Drenth
Kurinchi Selvan Gurusamy
Cornelis Jhm van Laarhoven
Radboud University Medical Center · NLUniversity College London · GBRadboud University Nijmegen · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundApproximately 0.6% to 4% of cholecystectomies are performed because of gallbladder polyps. The decision to perform cholecystectomy is based on presence of gallbladder polyp(s) on transabdominal ultrasound (TAUS) or endoscopic ultrasound (EUS), or both. These polyps are currently considered for surgery if they grow more than 1 cm. However, non-neoplastic polyps (pseudo polyps) do not need surgery, even when they are larger than 1 cm. True polyps are neoplastic, either benign (adenomas) or (pre)malignant (dysplastic polyps/carcinomas). True polyps need surgery, especially if they are premalignant or malignant. There has been no systematic review and meta-analysis on the accuracy of TAUS and EUS in the diagnosis of gallbladder polyps, true gallbladder polyps, and (pre)malignant polyps.

objectivesTo summarise and compare the accuracy of transabdominal ultrasound (TAUS) and endoscopic ultrasound (EUS) for the detection of gallbladder polyps, for differentiating between true and pseudo gallbladder polyps, and for differentiating between dysplastic polyps/carcinomas and adenomas/pseudo polyps of the gallbladder in adults. SEARCH

methodsWe searched the Cochrane Library, MEDLINE, Embase, Science Citation Index Expanded, and trial registrations (last date of search 09 July 2018). We had no restrictions regarding language, publication status, or prospective or retrospective nature of the studies. SELECTION CRITERIA: Studies reporting on the diagnostic accuracy data (true positive, false positive, false negative and true negative) of the index test (TAUS or EUS or both) for detection of gallbladder polyps, differentiation between true and pseudo polyps, or differentiation between dysplastic polyps/carcinomas and adenomas/pseudo polyps. We only accepted histopathology after cholecystectomy as the reference standard, except for studies on diagnosis of gallbladder polyp. For the latter studies, we also accepted repeated imaging up to six months by TAUS or EUS as the reference standard. DATA COLLECTION AND ANALYSIS: Two authors independently screened abstracts, selected studies for inclusion, and collected data from each study. The quality of the studies was evaluated using the QUADAS-2 tool. The bivariate random-effects model was used to obtain summary estimates of sensitivity and specificity, to compare diagnostic performance of the index tests, and to assess heterogeneity. MAIN

resultsA total of 16 studies were included. All studies reported on TAUS and EUS as separate tests and not as a combination of tests. All studies were at high or unclear risk of bias, ten studies had high applicability concerns in participant selection (because of inappropriate participant exclusions) or reference standards (because of lack of follow-up for non-operated polyps), and three studies had unclear applicability concerns in participant selection (because of high prevalence of gallbladder polyps) or index tests (because of lack of details on ultrasound equipment and performance). A meta-analysis directly comparing results of TAUS and EUS in the same population could not be performed because only limited studies executed both tests in the same participants. Therefore, the results below were obtained only from indirect test comparisons. There was significant heterogeneity amongst all comparisons (target conditions) on TAUS and amongst studies on EUS for differentiating true and pseudo polyps.Detection of gallbladder polyps: Six studies (16,260 participants) used TAUS. We found no studies on EUS. The summary sensitivity and specificity of TAUS for the detection of gallbladder polyps was 0.84 (95% CI 0.59 to 0.95) and 0.96 (95% CI 0.92 to 0.98), respectively. In a cohort of 1000 people, with a 6.4% prevalence of gallbladder polyps, this would result in 37 overdiagnosed and seven missed gallbladder polyps.Differentiation between true polyp and pseudo gallbladder polyp: Six studies (1078 participants) used TAUS; the summary sensitivity was 0.68 (95% CI 0.44 to 0.85) and the summary specificity was 0.79 (95% CI 0.57 to 0.91). Three studies (209 participants) used EUS; the summary sensitivity was 0.85 (95% CI 0.46 to 0.97) and the summary specificity was 0.90 (95% CI 0.78 to 0.96). In a cohort of 1000 participants with gallbladder polyps, with 10% having true polyps, this would result in 189 overdiagnosed and 32 missed true polyps by TAUS, and 90 overdiagnosed and 15 missed true polyps by EUS. There was no evidence of a difference between the diagnostic accuracy of TAUS and EUS (relative sensitivity 1.06, P = 0.70, relative specificity 1.15, P = 0.12).Differentiation between dysplastic polyps/carcinomas and adenomas/pseudo polyps of the gallbladder: Four studies (1,009 participants) used TAUS; the summary sensitivity was 0.79 (95% CI 0.62 to 0.90) and the summary specificity was 0.89 (95% CI 0.68 to 0.97). Three studies (351 participants) used EUS; the summary sensitivity was 0.86 (95% CI 0.76 to 0.92) and the summary specificity was 0.92 (95% CI 0.85 to 0.95). In a cohort of 1000 participants with gallbladder polyps, with 5% having a dysplastic polyp/carcinoma, this would result in 105 overdiagnosed and 11 missed dysplastic polyps/carcinomas by TAUS and 76 overdiagnosed and seven missed dysplastic polyps/carcinomas by EUS. There was no evidence of a difference between the diagnostic accuracy of TAUS and EUS (log likelihood test P = 0.74). AUTHORS'

conclusionsAlthough TAUS seems quite good at discriminating between gallbladder polyps and no polyps, it is less accurate in detecting whether the polyp is a true or pseudo polyp and dysplastic polyp/carcinoma or adenoma/pseudo polyp. In practice, this would lead to both unnecessary surgeries for pseudo polyps and missed cases of true polyps, dysplastic polyps, and carcinomas. There was insufficient evidence that EUS is better compared to TAUS in differentiating between true and pseudo polyps and between dysplastic polyps/carcinomas and adenomas/pseudo polyps. The conclusions are based on heterogeneous studies with unclear criteria for diagnosis of the target conditions and studies at high or unclear risk of bias. Therefore, results should be interpreted with caution. Further studies of high methodological quality, with clearly stated criteria for diagnosis of gallbladder polyps, true polyps, and dysplastic polyps/carcinomas are needed to accurately determine diagnostic accuracy of EUS and TAUS.

Indexed as

AdenomaAdultCarcinomaDiagnosis, DifferentialEndosonographyGallbladder DiseasesGallbladder NeoplasmsHumansPolypsSensitivity and SpecificityUltrasonography

Identifiers

PMID30109701
PMCPMC6513652
OpenAlexW2775857256

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.