Evidence map›Paper›PMID 30107082›Full record

ArticleCytometry. Part A : the journal of the International Society for Analytical Cytology2018

The Parsortix™ Cell Separation System-A versatile liquid biopsy platform.

M Craig Miller, Peggy S Robinson, Christopher Wagner, Daniel J O'Shannessy

Registry-linked trialAbstract read
In one paragraph

Article in Cytometry. Part A : the journal of the International Society for Analytical Cytology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT05437679 (ANG-015 / MLU-3), which is not on this map. Cited by 109 papers.

0numbers the graph read from it
0cells of the map it votes in
109citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT05437679 terminatednot on this mapstarted 2022, after this paper: background citation

ANG-015 / MLU-3 (CHARTER Study): Characterization of Circulating Tumor Cells Isolated Using the Parsortix® System in High Risk and Early Metastatic Prostate Cancer Patients

TypeobservationalSponsorAngle plcRan2022 to 2023Enrolled9ConditionsHigh Risk Prostate Carcinoma, Biochemically Recurrent Prostate Carcinoma, Castration-resistant Prostate Cancer, Prostate CancerArmsBlood collection
3 · Its place in the literature

Who cites it

109 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
  4. Feasibility ofGeburtshilfe und Frauenheilkunde · 2026
    Article
  5. Circulating Tumor Cells: Emerging Frontiers in Cancer Technology.Expert reviews in molecular medicine · 2026
    Review
  6. Review
  7. Review
  8. Review
  9. Article
  10. Article
  11. Article
  12. Review
  13. Article
  14. Article
  15. Review
  16. Review
  17. Review
  18. Review
  19. Review
  20. Article

49 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

M Craig MillerANGLE North America, Inc., Clinical Development, King of Prussia, Pennsylvania.
Peggy S RobinsonANGLE North America, Inc., Corporate, King of Prussia, Pennsylvania.
Christopher WagnerANGLE North America, Inc., Commercial Operations, King of Prussia, Pennsylvania.
Daniel J O'ShannessyANGLE North America, Inc., Research & Development, King of Prussia, Pennsylvania.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Cancer cells from solid tumors can enter the circulatory system and survive to subsequently form distant metastases. The CellSearch® system (Menarini-Silicon Biosystems, Huntingdon Valley, PA) was the first, FDA-cleared system that provided a reliable tool for the investigation of circulating tumor cells (CTCs), which have been shown to be strongly associated with poor survival and therapy failure. Since that time, a number of new technologies have been introduced to improve CTC detection and/or isolation for further characterization. The continued and growing interest in the "liquid biopsy" field has spurred the development of numerous different CTC technologies. However, selecting the most appropriate CTC platform for individual applications can be challenging. No consensus has yet been reached in the community regarding which liquid biopsy technology is optimal. Here, we introduce the Parsortix™ Cell Separation System (ANGLE North America, Inc., King of Prussia, PA), a microfluidic based technology that captures rare cells based on size and deformability, offers reproducibly high capture efficiency, and produces highly enriched, viable (viability dependent on preservative used) CTCs that are amenable to a multitude of downstream analyses, including the isolation and interrogation of single cells. © 2018 The Authors. Cytometry Part A published by Wiley Periodicals, Inc. on behalf of International Society for Advancement of Cytometry.

Indexed as

Cell CountCell Line, TumorCell SeparationCell SizeHumansLiquid BiopsyMCF-7 CellsMicrofluidicsNeoplastic Cells, Circulatingcirculating tumor cellliquid biopsymicrofluidicsrare cell isolation

Identifiers

PMID30107082
PMCPMC6586069

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.