Evidence map›Paper›PMID 30104055›Full record

ArticleJournal of biomechanics2018

Joint contact stresses calculated for acetabular dysplasia patients using discrete element analysis are significantly influenced by the applied gait pattern.

Holly D Thomas-Aitken, Michael C Willey, Jessica E Goetz

Abstract read
In one paragraph

Article in Journal of biomechanics, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Persistently elevated joint contact stress after periacetabular osteotomy is associated with joint failure at minimum 10-year follow-up.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2024
    Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Holly D Thomas-AitkenDepartment of Orthopedics and Rehabilitation, University of Iowa, Iowa City, IA, USA; Department of Biomedical Engineering, University of Iowa, Iowa City, IA, USA.
Michael C WilleyDepartment of Orthopedics and Rehabilitation, University of Iowa, Iowa City, IA, USA.
Jessica E GoetzDepartment of Orthopedics and Rehabilitation, University of Iowa, Iowa City, IA, USA; Department of Biomedical Engineering, University of Iowa, Iowa City, IA, USA. Electronic address: jessica-goetz@uiowa.edu.

Funding

Tissue and Experimental Modeling CoreP50AR055533 · NIAMS · UNIVERSITY OF IOWA · PI GOETZ, JESSICA E · 2007 to 2016
$14.9M
NIAMS NIH HHS P50 AR055533
6 · The paper itself

Abstract

Gait modifications in acetabular dysplasia patients may influence cartilage contact stress patterns within the hip joint, with serious implications for clinical outcomes and the risk of developing osteoarthritis. The objective of this study was to understand how the gait pattern used to load computational models of dysplastic hips influences computed joint mechanics. Three-dimensional pre- and post-operative hip models of thirty patients previously treated for hip dysplasia with periacetabular osteotomy (PAO) were developed for performing discrete element analysis (DEA). Using DEA, contact stress patterns were calculated for each pre- and post-operative hip model when loaded with an instrumented total hip, a dysplastic, a matched control, and a normal gait pattern. DEA models loaded with the dysplastic and matched control gait patterns had significantly higher (p = 0.012 and p < 0.001) average pre-operative maximum contact stress than models loaded with the normal gait. Models loaded with the dysplastic and matched control gait patterns had nearly significantly higher (p = 0.051) and significantly higher (p = 0.008) average pre-operative contact stress, respectively, than models loaded with the instrumented hip gait. Following PAO, the average maximum contact stress for DEA models loaded with the dysplastic and matched control patterns decreased, which was significantly different (p < 0.001) from observed increases in maximum contact stress calculated when utilizing the instrumented hip and normal gait patterns. The correlation between change in DEA-computed maximum contact stress and the change in radiographic measurements of lateral center-edge angle were greatest (R

Indexed as

GaitAcetabulumAdolescentAdultCartilageCartilage, ArticularComputer SimulationFemaleFinite Element AnalysisHip DislocationHip Dislocation, CongenitalHip JointHumansMaleMiddle AgedOsteotomyAcetabular dysplasiaContact stressDiscrete element analysisGaitPeriacetabular osteotomy

Identifiers

PMID30104055
PMCPMC6237088

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked