Evidence map›Paper›PMID 30102431›Full record

ArticleJournal of magnetic resonance imaging : JMRI2019

Uteroplacental and Fetal 4D Flow MRI in the Pregnant Rhesus Macaque.

Jacob A Macdonald, Philip A Corrado, Sydney M Nguyen, Kevin M Johnson, Christopher J Francois, Ronald R Magness, Dinesh M Shah, Thaddeus G Golos, Oliver Wieben

Open access · greenAbstract read
In one paragraph

Article in Journal of magnetic resonance imaging : JMRI, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed
2.8field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed, 28 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Review
  5. Repeatability and reproducibility of various 4D Flow MRI postprocessing software programs in a multi-software and multi-vendor cross-over comparison study.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2023
    Article
  6. Review
  7. Article
  8. Article
  9. Abdominal applications of quantitative 4D flow MRI.Abdominal radiology (New York) · 2022
    Review
  10. Nonhuman Primates in Translational Research.Annual review of animal biosciences · 2022
    Review
  11. Fetal Neuroimaging Updates.Magnetic resonance imaging clinics of North America · 2021
    Review
  12. The application ofJournal of developmental origins of health and disease · 2021
    Review
  13. Article
  14. Article
  15. Review
  16. Fetal hemodynamics and cardiac streaming assessed by 4D flow cardiovascular magnetic resonance in fetal sheep.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2019
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 1 country.

Jacob A MacdonaldDepartment of Medical Physics, University of Wisconsin - Madison, Madison, Wisconsin, USA.ORCID 0000-0002-8463-7628
Philip A CorradoDepartment of Medical Physics, University of Wisconsin - Madison, Madison, Wisconsin, USA.
Sydney M NguyenWisconsin National Primate Center, University of Wisconsin - Madison, Madison, Wisconsin, USA.
Kevin M JohnsonDepartment of Medical Physics, University of Wisconsin - Madison, Madison, Wisconsin, USA.
Christopher J FrancoisDepartment of Radiology, University of Wisconsin - Madison, Madison, Wisconsin, USA.
Ronald R MagnessDepartment of Obstetrics & Gynecology, University of South Florida, Tampa, Florida, USA.
Dinesh M ShahDepartment of Obstetrics & Gynecology, University of Wisconsin - Madison, Madison, Wisconsin, USA.
Thaddeus G GolosWisconsin National Primate Center, University of Wisconsin - Madison, Madison, Wisconsin, USA.
Oliver WiebenDepartment of Medical Physics, University of Wisconsin - Madison, Madison, Wisconsin, USA.
University of Wisconsin–Madison · USUniversity of South Florida · US

Funding

WNPRC Supplemental Request for Nonhuman Primate Enclosures to Equip HIV/AIDS-Related Research FacilitiesP51OD011106 · OD · UNIVERSITY OF WISCONSIN-MADISON · PI Dorota A. Grejner-Brzezinska · 2012 to 2026
$150.7M
University of Wisconsin Institute for Clinical and Translational ResearchUL1TR002373 · NCATS · UNIVERSITY OF WISCONSIN-MADISON · PI ELIZABETH S BURNSIDE, Allan R. Brasier · 2017 to 2026
$75.9M
Institutional Clinical and Translational Science AwardUL1TR000427 · NCATS · UNIVERSITY OF WISCONSIN-MADISON · PI DREZNER, MARC KENNETH · 2012 to 2016
$32.2M
Advanced MRI FOR Uteroplacental Flow, Perfusion, Oxygenation & InflammationU01HD087216 · NICHD · UNIVERSITY OF WISCONSIN-MADISON · PI SHAH, DINESH MANILAL, WIEBEN, OLIVER · 2015 to 2015
$4.0M
Endothelial Function in a Model of IUGR Induced by Uterine Space RestrictionR01HL117341 · NHLBI · UNIVERSITY OF WISCONSIN-MADISON · PI MAGNESS, RONALD R · 2014 to 2017
$1.8M
National Institutes of Health (NIH) NIH CTSA UW-ICTR UL1TR000427National Institutes of Health (NIH) P51OD011106 (to the Wisconsin National Primate Center)National Institutes of Health (NIH) U01HD087216 (to D.S. and O.W.)NCATS NIH HHS UL1 TR000427NCATS NIH HHS UL1 TR002373NHLBI NIH HHS R01 HL117341NICHD NIH HHS U01 HD087216NIH HHS P51 OD011106
6 · The paper itself

Abstract

backgroundPregnancy complications are often associated with poor uteroplacental vascular adaptation and standard diagnostics are unable to reliably quantify flow in all uteroplacental vessels and have poor sensitivity early in gestation. PURPOSE: To investigate the feasibility of using 4D flow MRI to assess total uteroplacental blood flow in pregnant rhesus macaques as a precursor to human studies. STUDY TYPE: Retrospective feasibility study. ANIMAL MODEL: Fifteen healthy, pregnant rhesus macaques ranging from the 1 FIELD STRENGTH/SEQUENCE: Abdominal 4D flow MRI was performed on a 3.0T scanner with a radially undersampled phase contrast (PC) sequence. Reference ferumoxytol-enhanced angiograms were acquired with a 3D ultrashort echo time sequence with a center-out radial trajectory. ASSESSMENT: Repeatability of flow measurements was assessed with scans performed same-day and on consecutive days in the uterine arteries and ovarian veins. In-flow was compared against out-flow in the uterus, umbilical cord, and fetal heart with a conservation of mass analysis. Conspicuity of uteroplacental vessels was qualitatively compared between PC angiograms derived from 4D flow data and ferumoxytol-enhanced angiograms. STATISTICAL TESTS: Bland-Altman analysis was used to quantify same-day and consecutive-day repeatability.

resultsSame-day flow measurements showed an average difference between scans of 13% in both the uterine arteries and ovarian veins, while consecutive-day measurements showed average differences of 22% and 24%, respectively. Comparisons of in-flow and out-flow showed average differences of 15% in the uterus, 8% in fetal heart, and 15% in the umbilical cord. PC angiograms showed similar depiction of main uteroplacental vessels as high-resolution, ferumoxytol-enhanced angiograms. DATA

conclusion4D flow MRI could be used in the rhesus macaque for repeatable flow measurements in the uteroplacental and fetal vasculature, setting the stage for future human studies. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;49:534-545.

Indexed as

Magnetic Resonance ImagingAnimalsFeasibility StudiesFemaleFerrosoferric OxideImage EnhancementImage Interpretation, Computer-AssistedImage Processing, Computer-AssistedImaging, Three-DimensionalMacaca mulattaMagnetic Resonance AngiographyPerfusionPlacentaPregnancyPregnancy, AnimalReproducibility of ResultsFerrosoferric Oxide

Identifiers

PMID30102431
PMCPMC6330144
OpenAlexW2886605745

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.