Quantitative accuracy of CT numbers: Theoretical analyses and experimental studies.

Ran Zhang, Juan P Cruz-Bastida, Daniel Gomez-Cardona, John W Hayes, Ke Li, Guang-Hong Chen

Abstract read
In one paragraph

Article in Medical physics, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Ran ZhangDepartment of Medical Physics, University of Wisconsin School of Medicine and Public Health, 1111 Highland Avenue, Madison, WI, 53705, USA.
Juan P Cruz-BastidaDepartment of Medical Physics, University of Wisconsin School of Medicine and Public Health, 1111 Highland Avenue, Madison, WI, 53705, USA.
Daniel Gomez-CardonaDepartment of Medical Physics, University of Wisconsin School of Medicine and Public Health, 1111 Highland Avenue, Madison, WI, 53705, USA.
John W HayesDepartment of Medical Physics, University of Wisconsin School of Medicine and Public Health, 1111 Highland Avenue, Madison, WI, 53705, USA.
Ke LiDepartment of Medical Physics, University of Wisconsin School of Medicine and Public Health, 1111 Highland Avenue, Madison, WI, 53705, USA.
Guang-Hong ChenDepartment of Medical Physics, University of Wisconsin School of Medicine and Public Health, 1111 Highland Avenue, Madison, WI, 53705, USA.

Funding

Ultra-Low Radiation Dose Body CT ImagingR01CA169331 · NCI · UNIVERSITY OF WISCONSIN-MADISON · PI CHEN, GUANG-HONG, PICKHARDT, PERRY · 2012 to 2016
$1.4M
NCI NIH HHS R01 CA169331
6 · The paper itself

Abstract

purposeThe CT number accuracy, that is, CT number bias, plays an important role in clinical diagnosis. When strategies to reduce radiation dose are discussed, it is important to make sure that the CT number bias is controlled within an acceptable range. The purpose of this paper was to investigate the dependence of CT number bias on radiation dose level and on image contrast (i.e., the difference in CT number between the ROI and the background) in Computed Tomography (CT).

methodsA lesion-background model was introduced to theoretically study how the CT number bias changes with radiation exposure level and with CT number contrast when a simple linear reconstruction algorithm such as filtered backprojection (FBP) is used. The theoretical results were validated with experimental studies using a benchtop CT system equipped with a photon-counting detector (XC-HYDRA FX50, XCounter AB, Sweden) and a clinical diagnostic MDCT scanner (Discovery CT750 HD, GE Healthcare, Waukesha, WI, USA) equipped with an energy-integrating detector. The Catphan phantom (Catphan 600, the Phantom Laboratory, Salem, NY, USA) was scanned at different mAs levels and 50 scans were performed for each mAs. The bias of CT number was evaluated for each combination of mAs and ROIs with different contrast levels. An anthropomorphic phantom (ATOM 10-year-old phantom, Model 706, CIRS Inc. Norfolk, VA, USA) with much more heterogeneous object content was used to test the applicability of the theory to the more general image object cases.

resultsBoth theoretical and experimental studies showed that the CT number bias is inversely proportional to the radiation exposure level yet linearly dependent on the CT number contrast between the lesion and the background, that is,

conclusionsThe quantitative accuracy of CT numbers can be problematic and thus needs some extra attention when radiation dose is reduced. In this work, we showed that the bias of the FBP reconstruction increases as mAs is reduced; both positive and negative bias can be observed depending on the contrast difference between a targeted ROI and its surrounding background tissues.

Indexed as

Models, TheoreticalImage Processing, Computer-AssistedPhantoms, ImagingPhotonsTomography, X-Ray Computedlow-dose CTphoton-counting detectorreconstruction bias

Identifiers

PMID30102414
PMCPMC7301593

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.