ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2019
Posterior capsular release is a biomechanically safe procedure to perform in total knee arthroplasty.
Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 14 citations in OpenAlex.
- The Addition of Posterolateral Tenodesis in Isolated PCL Injuries and in Combination With Fanelli Type A Lesion of the Posterolateral Corner Decreases Rotatory Instability: A Biomechanical Study in Human Cadaveric Knees.Orthopaedic journal of sports medicine · 2026Article
- Management of fixed flexion contracture in primary total knee arthroplasty: recent systematic review.SICOT-J · 2024Article
- Limited medial posterior capsular release increases the intraoperative medial component gap while maintaining the joint varus angle at extension in posterior-stabilized total knee arthroplasty.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2023Article
- An Anterior Cruciate Ligament In Vitro Rupture Model Based on Clinical Imaging.The American journal of sports medicine · 2021Article
- Correcting severe flexion contracture with fusiform capsulectomy of posterior capsule during total knee arthroplasty.International orthopaedics · 2021Article
- Simulation of preoperative flexion contracture in a computational model of total knee arthroplasty: Development and evaluation.Journal of biomechanics · 2021Article
- The effect of hamstring tightness on intraoperative extension gap in posterior stabilized total knee arthroplasty.Scientific reports · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeSurgeons may attempt to strip the posterior capsule from its femoral attachment to overcome flexion contracture in total knee arthroplasty (TKA); however, it is unclear if this impacts anterior-posterior (AP) laxity of the implanted knee. The aim of the study was to investigate the effect of posterior capsular release on AP laxity in TKA, and compare this to the restraint from the posterior cruciate ligament (PCL).
methodsEight cadaveric knees were mounted in a six degree of freedom testing rig and tested at 0°, 30°, 60° and 90° flexion with ± 150 N AP force, with and without a 710 N axial compressive load. After the native knee was tested, a deep dished cruciate-retaining TKA was implanted and the tests were repeated. The PCL was then cut, followed by releasing the posterior capsule using a curved osteotome.
resultsWith 0 N axial load applied, cutting the PCL as well as releasing the posterior capsule significantly increased posterior laxity compared to the native knee at all flexion angles, and CR TKA states at 30°, 60° and 90° (p < 0.05). However, no significant increase in laxity was found between cutting the PCL and subsequent PostCap release (n.s.). In anterior drawer, there was a significant increase of 1.4 mm between cutting the PCL and PostCap release at 0°, but not at any other flexion angles (p = 0.021). When a 710 N axial load was applied, there was no significant difference in anterior or posterior translation across the different knee states (n.s.).
conclusionsPosterior capsular release only caused a small change in AP laxity compared to cutting the PCL and, therefore, may not be considered detrimental to overall AP stability if performed during TKA surgery. LEVEL OF EVIDENCE: Controlled laboratory study.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials