ReviewJMIR mHealth and uHealth2018
Accuracy of Fitbit Devices: Systematic Review and Narrative Syntheses of Quantitative Data.
Review in JMIR mHealth and uHealth, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 283 papers, 13 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Proof-of-Concept of the SOAR (Stop OsteoARthritis) Program: A Randomized Delayed-Control Trial
Targeting Metabolic Syndrome From the Emergency Department Through Mixed-Methods: Pilot Trial
Who cites it
283 citing papers in PubMed, 13 syntheses or guidelines pooled it, 637 citations in OpenAlex.
- Effectiveness of interventions using activity trackers and smartphone applications for increasing physical activity in older adults with health conditions: a systematic review with meta-analysis.The Journal of frailty & aging · 2026Pooled it
- Activity and Behavioral Recognition Using Sensing Technology in Persons with Parkinson's Disease or Dementia: An Umbrella Review of the Literature.Sensors (Basel, Switzerland) · 2025Pooled it
- Keeping Pace with Wearables: A Living Umbrella Review of Systematic Reviews Evaluating the Accuracy of Consumer Wearable Technologies in Health Measurement.Sports medicine (Auckland, N.Z.) · 2024Pooled it
- Current Knowledge about ActiGraph GT9X Link Activity Monitor Accuracy and Validity in Measuring Steps and Energy Expenditure: A Systematic Review.Sensors (Basel, Switzerland) · 2024Pooled it
- Wearable Devices to Improve Physical Activity and Reduce Sedentary Behaviour: An Umbrella Review.Sports medicine - open · 2024Pooled it
- Assessment of 24-hour physical behaviour in adults via wearables: a systematic review of validation studies under laboratory conditions.The international journal of behavioral nutrition and physical activity · 2023Pooled it
- Health-Related Telemonitoring Parameters/Signals of Older Adults: An Umbrella Review.Sensors (Basel, Switzerland) · 2023Pooled it
- Accuracy and Precision of Consumer-Grade Wearable Activity Monitors for Assessing Time Spent in Sedentary Behavior in Children and Adolescents: Systematic Review.JMIR mHealth and uHealth · 2022Pooled it
- The Influence of Wearables on Health Care Outcomes in Chronic Disease: Systematic Review.Journal of medical Internet research · 2022Pooled it
- Quality Evaluation of Free-living Validation Studies for the Assessment of 24-Hour Physical Behavior in Adults via Wearables: Systematic Review.JMIR mHealth and uHealth · 2022Pooled it
- Accuracy and Precision of Energy Expenditure, Heart Rate, and Steps Measured by Combined-Sensing Fitbits Against Reference Measures: Systematic Review and Meta-analysis.JMIR mHealth and uHealth · 2022Pooled it
- Accuracy and Acceptability of Wrist-Wearable Activity-Tracking Devices: Systematic Review of the Literature.Journal of medical Internet research · 2022Pooled it
- Assessment of 24-hour physical behaviour in children and adolescents via wearables: a systematic review of free-living validation studies.BMJ open sport & exercise medicine · 2022Pooled it
- Effects of web platform delivery of a physical activity program for breast cancer survivors: a randomized controlled trial.Journal of cancer survivorship : research and practice · 2026Trial
- Stem Cell Transplant Patients' Activity Decline, Outpatient Resumption, and Intervention Effectiveness Identified by Wearable Activity Monitoring.Medicine and science in sports and exercise · 2026Trial
- Adherence to Accelerometer Use in Older Adults Undergoing mHealth Cardiac Rehabilitation: Secondary Analysis of a Randomized Clinical Trial.Journal of medical Internet research · 2025Trial
- Comparing sleep measures in cancer survivors: self-reported sleep diary versus objective wearable sleep tracker.Supportive care in cancer : official journal of the Multinational Association of Supportive Care in Cancer · 2024Trial
- Microdosing with psilocybin mushrooms: a double-blind placebo-controlled study.Translational psychiatry · 2022Trial
- Bringing usability testing to the front lines: IV smart pump evaluation with critical care nurses at a national conference.MethodsX · 2026Article
- Article
223 more citing papers are in PubMed but not listed here.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundAlthough designed as a consumer product to help motivate individuals to be physically active, Fitbit activity trackers are becoming increasingly popular as measurement tools in physical activity and health promotion research and are also commonly used to inform health care decisions.
objectiveThe objective of this review was to systematically evaluate and report measurement accuracy for Fitbit activity trackers in controlled and free-living settings.
methodsWe conducted electronic searches using PubMed, EMBASE, CINAHL, and SPORTDiscus databases with a supplementary Google Scholar search. We considered original research published in English comparing Fitbit versus a reference- or research-standard criterion in healthy adults and those living with any health condition or disability. We assessed risk of bias using a modification of the Consensus-Based Standards for the Selection of Health Status Measurement Instruments. We explored measurement accuracy for steps, energy expenditure, sleep, time in activity, and distance using group percentage differences as the common rubric for error comparisons. We conducted descriptive analyses for frequency of accuracy comparisons within a ±3% error in controlled and ±10% error in free-living settings and assessed for potential bias of over- or underestimation. We secondarily explored how variations in body placement, ambulation speed, or type of activity influenced accuracy.
resultsWe included 67 studies. Consistent evidence indicated that Fitbit devices were likely to meet acceptable accuracy for step count approximately half the time, with a tendency to underestimate steps in controlled testing and overestimate steps in free-living settings. Findings also suggested a greater tendency to provide accurate measures for steps during normal or self-paced walking with torso placement, during jogging with wrist placement, and during slow or very slow walking with ankle placement in adults with no mobility limitations. Consistent evidence indicated that Fitbit devices were unlikely to provide accurate measures for energy expenditure in any testing condition. Evidence from a few studies also suggested that, compared with research-grade accelerometers, Fitbit devices may provide similar measures for time in bed and time sleeping, while likely markedly overestimating time spent in higher-intensity activities and underestimating distance during faster-paced ambulation. However, further accuracy studies are warranted. Our point estimations for mean or median percentage error gave equal weighting to all accuracy comparisons, possibly misrepresenting the true point estimate for measurement bias for some of the testing conditions we examined.
conclusionsOther than for measures of steps in adults with no limitations in mobility, discretion should be used when considering the use of Fitbit devices as an outcome measurement tool in research or to inform health care decisions, as there are seemingly a limited number of situations where the device is likely to provide accurate measurement.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.