Evidence map›Paper›PMID 30092081›Full record

SynthesisPloS one2018

Complications of bone-anchored prostheses for individuals with an extremity amputation: A systematic review.

Robin Atallah, Ruud A Leijendekkers, Thomas J Hoogeboom, Jan Paul Frölke

Open access · goldAbstract readSystematic Review
In one paragraph

Synthesis in PloS one, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 39 papers, 4 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
39citing papers in PubMed, 4 pooled it
7.1field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

39 citing papers in PubMed, 4 syntheses or guidelines pooled it, 87 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Pooled it
  4. Pooled it
  5. Trial
  6. Review
  7. Article
  8. Article
  9. Article
  10. Article
  11. Review
  12. Review
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. ReliableFrontiers in bioengineering and biotechnology · 2024
    Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Robin AtallahDepartment of Orthopaedics, Radboud university medical center, Nijmegen, the Netherlands.ORCID 0000-0002-4127-6105
Ruud A LeijendekkersDepartment of Orthopaedics, Physical Therapy, Radboud university medical center, Nijmegen, the Netherlands.
Thomas J HoogeboomDepartment of Orthopaedics, Physical Therapy, Radboud university medical center, Nijmegen, the Netherlands.
Jan Paul FrölkeDepartment of Surgery, Radboud university medical center, Nijmegen, the Netherlands.
Radboud University Nijmegen · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThis study aimed to provide an overview of device-related complications occurring in individuals with an upper or lower extremity amputation treated with a screw, press-fit or other type of bone-anchored implant as well as interventions related to these complications.

methodA systematic literature search was conducted in the MEDLINE, Cochrane, EMBASE, CINAHL and Web of Science databases. The included studies reported on device-related complications and interventions occurring in individuals with bone-anchored prostheses. The outcomes evaluated were death, infection, bone/device breakage, implant loosening, soft tissue complications, systemic events, antibiotic and surgical treatment. Subgroup analyses were performed for the following groups: a) implant type (screw, press-fit and other types of implants) and b) level of amputation (transfemoral, transtibial and upper extremity amputation).

resultsOf 309 studies, 12 cohort studies were eligible for inclusion, all of which had methodological shortcomings and 12 studies were excluded due to complete overlap of patient data. Implant infection were rare in certain transfemoral implants (screw: 2-11%, press-fit: 0-3%, Compress: 0%) but common in transtibial implants (29%). The same was observed for implant loosening, in transfemoral (screw: 6%, press-fit: 0-3%, Compress: 0%), transtibial implants (29%) as well as for upper extremity implants (13-23%). Intramedullary device breakage were rare in transfemoral implants (screw: 0%, press-fit: 1%, Compress: unknown) but frequent in individuals with transradial implants (27%) and absent in transtibial implants. Soft tissue infections and complications were common and underreported in most articles.

conclusionsMajor complications (e.g. implant infection, implant loosening and intramedullary device breakage) are rare in transfemoral bone-anchored prosthesis and seem to occur less frequently in individuals with press-fit implants. Minor complications, such as soft tissue infections and complications, are common but are substantially influenced by the learning curve, implant design and surgical technique. Data for patients treated with a transtibial, upper extremity or Compress implant are underreported, precluding definitive conclusions. There is a need for either an international database to report on or a standard core set of complications as well as the need to follow classification systems that result in unequivocal data.

Indexed as

Amputation, SurgicalBone-Anchored ProsthesisPostoperative ComplicationsHumansLower ExtremityUpper Extremity

Identifiers

PMID30092081
PMCPMC6084937
OpenAlexW2885057207

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.