Evidence map›Paper›PMID 30082572›Full record

Trial reportThe Indian journal of medical research2018

A randomized controlled study of bedside electrocardiograph-guided tip location technique & the traditional chest radiography tip location technique for peripherally inserted central venous catheter in cancer patients.

AiMin Li, JianGuo Jiao, Ying Zhang, Li Tian, JinHong Miao, XiaoLi Hao, ZhenChang Sun, QiaoZhi Sun

Open access · diamondAbstract readRandomized Controlled Trial
In one paragraph

Trial report in The Indian journal of medical research, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
3.4field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 27 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Intracavitary electrocardiography for femorally inserted central catheter tip location in adult patients.Annals of noninvasive electrocardiology : the official journal of the International Society for Holter and Noninvasive Electrocardiology, Inc · 2022
    Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

AiMin LiDepartment of Oncology, Lymphoma Diagnosis & Treatment Center of Henan Province, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, PR China.
JianGuo JiaoDepartment of Nuclear Medicine, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, PR China.
Ying ZhangDepartment of Oncology, Lymphoma Diagnosis & Treatment Center of Henan Province, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, PR China.
Li TianDepartment of Oncology, Lymphoma Diagnosis & Treatment Center of Henan Province, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, PR China.
JinHong MiaoComprehensive Medical Department, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, PR China.
XiaoLi HaoDepartment of Oncology, Lymphoma Diagnosis & Treatment Center of Henan Province, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, PR China.
ZhenChang SunDepartment of Oncology, Lymphoma Diagnosis & Treatment Center of Henan Province, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, PR China.
QiaoZhi SunDepartment of Oncology, Lymphoma Diagnosis & Treatment Center of Henan Province, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, PR China.
First Affiliated Hospital of Zhengzhou University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background & objectives: The peripherally inserted central catheter (PICC) has the advantages of higher safety, lower infection rate and longer retention time than peripherally inserted catheter. This study was aimed to evaluate the accuracy and safety of bedside electrocardiograph (ECG)-guided tip location technique in PICC in cancer patients, and compared with traditional chest radiography tip location technique. Methods: Patients were randomly assigned into two groups: The ECG test group patients underwent PICC insertion with ECG-guided tip location, while the control group patients had PICC insertion by the conventional method. The precision of tip location was verified by chest radiography in both groups. The groups were compared with regard to the accuracy of tip placement, anxiety levels before and after the procedure; medical cost and incidence of complications at one week, three months and six months after PICC insertion. Results: Accurate tip location was achieved in 99.30 per cent in the ECG test group vs 92.30 per cent in the control group (P<0.001). At 24 h after the procedure, the anxiety level was significantly lower in the ECG test group. The presence of thrombogenesis was significantly lower in the ECG test group at both three months and six months after the procedure (P=0.04 and P=0.03, respectively). Interpretation & conclusions: The ECG-guided PICC tip location technique was accurate and caused fewer procedure-related complications and less anxiety in patients compared to chest radiography tip location technique. Radiographic confirmation of PICC tip position may not be needed when ECG guidance is used and thus it can help avoid radiation exposure.

Indexed as

ElectrocardiographyRadiography, ThoracicCatheterization, Central VenousCentral Venous CathetersChinaHumansNeoplasmsPilot ProjectsRadiographyAnxiety - chest radiograph - complications - electrocardiograph-guided - tip location

Identifiers

PMID30082572
PMCPMC6094514
OpenAlexW2887668010

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.