ReviewHuman brain mapping2018
From simultaneous to synergistic MR-PET brain imaging: A review of hybrid MR-PET imaging methodologies.
Review in Human brain mapping, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 26 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
26 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Pooled it
- Monash DaCRA fPET-fMRI: A dataset for comparison of radiotracer administration for high temporal resolution functional FDG-PET.GigaScience · 2022Trial
- Comparison of Magnetic Resonance Spectra Acquired With Hybrid PET/MR and Standalone MR Scanners.Journal of magnetic resonance imaging : JMRI · 2025Article
- Impact of Mechanical Ventilation and Anesthesia on PET Tracer Kinetics for Combined PET/fMRI Studies in Rats.Molecular imaging and biology · 2025Article
- Topographic metabolism-function relationships in Alzheimer's disease: A simultaneous PET/MRI study.Human brain mapping · 2024Article
- Improving portable low-field MRI image quality through image-to-image translation using paired low- and high-field images.Scientific reports · 2023Article
- Impact of brain segmentation methods on regional metabolism quantification inEJNMMI research · 2023Article
- Neurophysiological consequences of synapse loss in progressive supranuclear palsy.Brain : a journal of neurology · 2023Article
- Highlighted Advances in Therapies for Difficult-To-Treat Brain Tumours Such as Glioblastoma.Pharmaceutics · 2023Review
- Metabolic and functional connectivity provide unique and complementary insights into cognition-connectome relationships.Cerebral cortex (New York, N.Y. : 1991) · 2023Article
- Analysis of Stable Chelate-free Gadolinium Loaded Titanium Dioxide Nanoparticles for MRI-Guided Radionuclide Stimulated Cancer Treatment.Current analytical chemistry · 2022Article
- Deep learning-based image reconstruction and post-processing methods in positron emission tomography for low-dose imaging and resolution enhancement.European journal of nuclear medicine and molecular imaging · 2022Review
- Integrated Positron Emission Tomography/Magnetic Resonance Imaging for Resting-State Functional and Metabolic Imaging in Human Brain: What Is Correlated and What Is Impacted.Frontiers in neuroscience · 2022Article
- CONN-NLM: A Novel CONNectome-Based Non-local Means Filter for PET-MRI Denoising.Frontiers in neuroscience · 2022Article
- Task-evoked simultaneous FDG-PET and fMRI data for measurement of neural metabolism in the human visual cortex.Scientific data · 2021Article
- MR-PET head motion correction based on co-registration of multicontrast MR images.Human brain mapping · 2021Article
- Augmented deep learning model for improved quantitative accuracy of MR-based PET attenuation correction in PSMA PET-MRI prostate imaging.European journal of nuclear medicine and molecular imaging · 2021Article
- Application of PET Imaging in the Brain Regions of the Emotional Control Loop in Patients with Generalized Anxiety Disorder.Journal of healthcare engineering · 2021Article
- Advances in multimodal data fusion in neuroimaging: Overview, challenges, and novel orientation.An international journal on information fusion · 2020Article
- Simultaneous BOLD-fMRI and constant infusion FDG-PET data of the resting human brain.Scientific data · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Simultaneous Magnetic Resonance Imaging (MRI) and Positron Emission Tomography (PET) scanning is a recent major development in biomedical imaging. The full integration of the PET detector ring and electronics within the MR system has been a technologically challenging design to develop but provides capacity for simultaneous imaging and the potential for new diagnostic and research capability. This article reviews state-of-the-art MR-PET hardware and software, and discusses future developments focusing on neuroimaging methodologies for MR-PET scanning. We particularly focus on the methodologies that lead to an improved synergy between MRI and PET, including optimal data acquisition, PET attenuation and motion correction, and joint image reconstruction and processing methods based on the underlying complementary and mutual information. We further review the current and potential future applications of simultaneous MR-PET in both systems neuroscience and clinical neuroimaging research. We demonstrate a simultaneous data acquisition protocol to highlight new applications of MR-PET neuroimaging research studies.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.