Evidence map›Paper›PMID 30075552›Full record

ArticleMedicine2018

Automated fastener (Core-Knot) versus manually tied knots in patients undergoing aortic valve replacement: Impact on cross-clamp time and short-term echocardiographic results.

Dan Loberman, Rephael Mohr, Paul A Pirundini, Farhang Yazdchi, Daniel Rinewalt, Tomer Ziv-Baran

Open access · goldAbstract readComparative Study
In one paragraph

Article in Medicine, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.2field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 2 countries.

Dan LobermanDivision of Cardiac Surgery, Brigham & Women's Hospital/Cape Cod Hospital, Harvard Medical School, Boston, MA Department of Epidemiology and Preventive Medicine, School of Public Health, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.
Rephael Mohr
Paul A Pirundini
Farhang Yazdchi
Daniel Rinewalt
Tomer Ziv-Baran
Brigham and Women's Hospital · USTel Aviv University · IL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The Core-Knot device is an automatic fastener used mainly in minimally invasive heart valve surgery procedures, to facilitate knot tying. The purpose of this report is to compare ischemic time and outcomes of surgical aortic valve replacements (SAVRs) utilizing the Core-Knot device compared with manually tied knots.Between January, 2014 and December, 2016, 119 patients underwent SAVR in Cape Cod Hospital. We compared patient's characteristics, cross-clamp time, and outcomes of 75 patients who underwent SAVR using Core-Knot to those of 44 operated using manually tied knots.Patient characteristics were similar between groups. Patients in the Core-Knot group had higher preoperative aortic valve area and higher ejection fraction. The use of Core-Knot was associated with reduced aortic cross-clamp time (median 70 vs 84 minutes; P < .001). Patients undergoing SAVR using Core-Knot were less likely to have postoperative aortic regurgitation (P < .001). Early mortality, and also the rates of early adverse events (including all cardiac, neurologic, and renal complications), and the immediate postprocedure echo findings were similar in the 2 groups. In multivariate analysis, the use of Core-Knot was associated with reduced postoperative mean gradient across the aortic valve and reduced occurrence of postoperative aortic regurgitation. Older age and larger valve size were other predictors of reduced postoperative mean gradients.The use of an automatic fastener (Core-Knot) in surgical aortic valve replacement cases reduce aortic cross-clamp time and help eliminate postoperative paravalvular aortic regurgitation.

Indexed as

Surgical InstrumentsAgedAortic ValveCohort StudiesEchocardiographyFemaleHumansMaleSuture TechniquesTime FactorsTranscatheter Aortic Valve ReplacementTreatment Outcome

Identifiers

PMID30075552
PMCPMC6081056
OpenAlexW2885624942

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked