ArticleJournal of diabetes science and technology2019
In Vitro Sugar Interference Testing With Amperometric Glucose Oxidase Sensors.
Article in Journal of diabetes science and technology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 19 citations in OpenAlex.
- Effect of Ethanol Consumption on the Accuracy of a Glucose Oxidase-Based Subcutaneous Glucose Sensor in Subjects with Type 1 Diabetes.Sensors (Basel, Switzerland) · 2022Trial
- The Impact of Interfering Substances on Continuous Glucose Monitors: Part 4: Continuous Glucose Monitoring Interferents: In Vivo Performance, Clinical Implications and Future Standardization.Journal of diabetes science and technology · 2026Review
- The Impact of Interfering Substances on Continuous Glucose Monitors Part 3: A Review of Non-Labeled Substances Influencing Continuous Glucose Monitor Readings.Journal of diabetes science and technology · 2026Review
- A portable potentiostat integrated with a Pt/ZnO/LIG electrode for non-enzymatic glucose detection.RSC advances · 2026Article
- Integrating Pharmacists into CGM-Enabled Digital Diabetes Care: Advancing Personalized and Data-Driven Management.Healthcare (Basel, Switzerland) · 2026Review
- Zero-current chronopotentiometry for wired biosensors.Mikrochimica acta · 2025Article
- Laboratory Protocol and Pilot Results for Dynamic Interference Testing of Continuous Glucose Monitoring Sensors.Journal of diabetes science and technology · 2024Article
- Perceptions of Continuous Glucose Monitoring Systems in the T1D Exchange Diabetes Registry: Satisfaction, Concerns, and Areas for Future Improvement.Clinical diabetes : a publication of the American Diabetes Association · 2024Article
- Cross-Linkable Polymer-Based Multi-layers for Protecting Electrochemical Glucose Biosensors against Uric Acid, Ascorbic Acid, and Biofouling Interferences.ACS sensors · 2023Article
- Use of Continuous Glucose Monitoring in the Assessment and Management of Patients With Diabetes and Chronic Kidney Disease.Frontiers in endocrinology · 2022Review
- Direct Bioelectrocatalytic Oxidation of Glucose byBiosensors · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundElectrochemical enzymatic glucose sensors are intended to measure blood or interstitial fluid glucose concentrations. One class of these glucose sensors are continuous glucose monitors (CGMs), indicated for tracking and trending of glucose concentrations in interstitial fluid and as an adjunct to blood glucose testing. Currently approved CGMs employ a glucose oxidase (GOx) electrochemical detection scheme. Potential interfering agents can impact the accuracy of results obtained by glucose sensors, including CGMs.
methodsSeven sugars, seven sugar alcohols, and three artificial sweeteners were in vitro screened for interference with amperometric glucose oxidase (GOx) sensors at concentrations greater than physiologic concentrations. Galactose was investigated further at physiologically relevant concentrations using a custom amperometric system. Furthermore, glucose and galactose calibration experiments were conducted to facilitate multiple enzyme kinetic analysis approaches (Michaelis-Menten and Hill equation) to understand the potential source and mechanism of interference from galactose.
resultsUnder in vitro testing, except for galactose, xylose and mannose, all screened compounds exhibited interference bias, expressed in mean absolute relative difference (MARD), of ⩽ 20% even at concentrations significantly higher than normal physiologic concentrations. Galactose exhibited, CGM-dependent, MARD of 47-72% and was subjected to further testing. The highest recorded mean relative difference (MRD) was 6.9 ± 1.3% when testing physiologically relevant galactose concentrations (0.1-10 mg/dL). Enzyme kinetic analysis provided calculations of maximum reaction rates (
conclusionUnder the conditions of in vitro screening, 14 of the 17 compounds did not exhibit measuarable interference. Galactose exhibited the highest interference during screening, but did not substantially interfere with CGMs under the conditions of in vitro testing at physiologically relevant concentrations. Enzyme kinetic analysis conducted with galactose supported the notion that (1) the reactivity of GOx enzyme toward nonglucose sugars and (2) the presence of enzymatic impurities (such as galactose oxidase) are two potential sources for sugar interference with GOx glucose sensors, and thus, should be considered during device development.