Evidence map›Paper›PMID 30071608›Full record

ArticleSensors (Basel, Switzerland)2018

On-The-Fly Ambiguity Resolution Based on Double-Differential Square Observation.

Tengfei Wang, Zheng Yao, Mingquan Lu

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Tengfei WangDepartment of Electronic Engineering, Tsinghua University, Beijing 100084, China. wtf13@mails.tsinghua.edu.cn.
Zheng YaoDepartment of Electronic Engineering, Tsinghua University, Beijing 100084, China. yaozheng@tsinghua.edu.cn.ORCID 0000-0002-7657-644X
Mingquan LuDepartment of Electronic Engineering, Tsinghua University, Beijing 100084, China. lumq@tsinghua.edu.cn.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Global navigation systems provide worldwide positioning, navigation and navigation services. However, in some challenging environments, especially when the satellite is blocked, the performance of GNSS is seriously degraded or even unavailable. Ground based positioning systems, including pseudolites and Locata, have shown their potentials in centimeter-level positioning accuracy using carrier phase measurements. Ambiguity resolution (AR) is a key issue for such high precision positioning. Current methods for the ground based systems need code measurements for initialization and/or approximating linearization. If the code measurements show relatively large errors, current methods might suffer from convergence difficulties in ground based positioning. In this paper, the concept of double-differential square observation (DDS) is proposed, and an on-the-fly ambiguity resolution (OTF-AR) method is developed for ground based navigation systems using two-way measurements. An important advantage of the proposed method is that only the carrier phase measurements are used, and code measurements are not necessary. The clock error is canceled out by two-way measurements between the rover and the base stations. The squared observations are then differenced between different rover positions and different base stations, and a linear model is then obtained. The floating integer values are easy to compute via this model, and there is no need to do approximate linearization. In this procedure, the rover's approximate coordinates are also directly obtained from the carrier measurements, therefore code measurements are not necessary. As an OTF-AR method, the proposed method relies on geometric changes caused by the rover's motion. As shown by the simulations, the geometric diversity of observations is the key factor for the AR success rate. Moreover, the fine floating solutions given by our method also have a fairly good accuracy, which is valuable when fixed solutions are not reliable. A real experiment is conducted to validate the proposed method. The results show that the fixed solution could achieve centimeter-level accuracy.

Indexed as

ambiguity resolutioncarrier phase measurementground based positioning

Identifiers

PMID30071608
PMCPMC6112075

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.