Evidence map›Paper›PMID 30071008›Full record

ArticlePloS one2018

Enhancing ventilation detection during cardiopulmonary resuscitation by filtering chest compression artifact from the capnography waveform.

Jose Julio Gutiérrez, Mikel Leturiondo, Sofía Ruiz de Gauna, Jesus María Ruiz, Luis Alberto Leturiondo, Digna María González-Otero, Dana Zive, James Knox Russell, Mohamud Daya

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.8field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 12 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. A review of ventilation in adult out-of-hospital cardiac arrest.Journal of the American College of Emergency Physicians open · 2020
    Review
  5. Article
  6. Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 2 countries.

Jose Julio GutiérrezDepartment of Communications Engineering, University of the Basque Country (UPV/EHU), Bilbao, Bizkaia, Spain.
Mikel LeturiondoDepartment of Communications Engineering, University of the Basque Country (UPV/EHU), Bilbao, Bizkaia, Spain.ORCID 0000-0001-9611-8596
Sofía Ruiz de GaunaDepartment of Communications Engineering, University of the Basque Country (UPV/EHU), Bilbao, Bizkaia, Spain.ORCID 0000-0002-0414-0946
Jesus María RuizDepartment of Communications Engineering, University of the Basque Country (UPV/EHU), Bilbao, Bizkaia, Spain.
Luis Alberto LeturiondoDepartment of Communications Engineering, University of the Basque Country (UPV/EHU), Bilbao, Bizkaia, Spain.
Digna María González-OteroDepartment of Communications Engineering, University of the Basque Country (UPV/EHU), Bilbao, Bizkaia, Spain.ORCID 0000-0002-6594-5748
Dana ZiveDepartment of Emergency Medicine, Oregon Health & Science University (OHSU), Portland, Oregon, United States of America.
James Knox RussellDepartment of Emergency Medicine, Oregon Health & Science University (OHSU), Portland, Oregon, United States of America.ORCID 0000-0002-5133-9720
Mohamud DayaDepartment of Emergency Medicine, Oregon Health & Science University (OHSU), Portland, Oregon, United States of America.
University of the Basque Country · ESOregon Health & Science University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundDuring cardiopulmonary resuscitation (CPR), there is a high incidence of capnograms distorted by chest compression artifact. This phenomenon adversely affects the reliability of automated ventilation detection based on the analysis of the capnography waveform. This study explored the feasibility of several filtering techniques for suppressing the artifact to improve the accuracy of ventilation detection. MATERIALS AND

methodsWe gathered a database of 232 out-of-hospital cardiac arrest defibrillator recordings containing concurrent capnograms, compression depth and transthoracic impedance signals. Capnograms were classified as non-distorted or distorted by chest compression artifact. All chest compression and ventilation instances were also annotated. Three filtering techniques were explored: a fixed-coefficient (FC) filter, an open-loop (OL) adaptive filter, and a closed-loop (CL) adaptive filter. The improvement in ventilation detection was assessed by comparing the performance of a capnogram-based ventilation detection algorithm with original and filtered capnograms.

resultsSensitivity and positive predictive value of the ventilation algorithm improved from 91.9%/89.5% to 97.7%/96.5% (FC filter), 97.6%/96.7% (OL), and 97.0%/97.1% (CL) for the distorted capnograms (42% of the whole set). The highest improvement was obtained for the artifact named type III, for which performance improved from 77.8%/74.5% to values above 95.5%/94.5%. In addition, errors in the measurement of ventilation rate decreased and accuracy in the detection of over-ventilation increased with filtered capnograms.

conclusionsCapnogram-based ventilation detection during CPR was enhanced after suppressing the artifact caused by chest compressions. All filtering approaches performed similarly, so the simplicity of fixed-coefficient filters would take advantage for a practical implementation.

Indexed as

ArtifactsCapnographyCardiopulmonary ResuscitationAlgorithmsHumansOut-of-Hospital Cardiac ArrestRespiration

Identifiers

PMID30071008
PMCPMC6072040
OpenAlexW2887144354

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.