Evidence map›Paper›PMID 30065641›Full record

ArticleFrontiers in human neuroscience2018

Effects of Training on Lateralization for Simulations of Cochlear Implants and Single-Sided Deafness.

Fei Yu, Hai Li, Xiaoqing Zhou, XiaoLin Tang, John J Galvin Iii, Qian-Jie Fu, Wei Yuan

Abstract read
In one paragraph

Article in Frontiers in human neuroscience, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Fei YuDepartment of Otolaryngology, Southwest Hospital, Third Military Medical University, Chongqing, China.
Hai LiDepartment of Otolaryngology, Southwest Hospital, Third Military Medical University, Chongqing, China.
Xiaoqing ZhouDepartment of Otolaryngology, Southwest Hospital, Third Military Medical University, Chongqing, China.
XiaoLin TangDepartment of Otolaryngology, Southwest Hospital, Third Military Medical University, Chongqing, China.
John J Galvin IiiHouse Ear Institute, Los Angeles, CA, United States.
Qian-Jie FuDepartment of Head and Neck Surgery, David Geffen School of Medicine, University of California, Los Angeles, Los Angeles, CA, United States.
Wei YuanDepartment of Otolaryngology, Southwest Hospital, Third Military Medical University, Chongqing, China.

Funding

Effects of Training on Adult Cochlear Implant UsersR01DC004792 · NIDCD · UNIVERSITY OF CALIFORNIA LOS ANGELES · PI FU, QIAN-JIE · 2001 to 2017
$5.5M
NIDCD NIH HHS R01 DC004792
6 · The paper itself

Abstract

While cochlear implantation has benefitted many patients with single-sided deafness (SSD), there is great variability in cochlear implant (CI) outcomes and binaural performance remains poorer than that of normal-hearing (NH) listeners. Differences in sound quality across ears-temporal fine structure (TFS) information with acoustic hearing vs. coarse spectro-temporal envelope information with electric hearing-may limit integration of acoustic and electric patterns. Binaural performance may also be limited by inter-aural mismatch between the acoustic input frequency and the place of stimulation in the cochlea. SSD CI patients must learn to accommodate these differences between acoustic and electric stimulation to maximize binaural performance. It is possible that training may increase and/or accelerate accommodation and further improve binaural performance. In this study, we evaluated lateralization training in NH subjects listening to broad simulations of SSD CI signal processing. A 16-channel vocoder was used to simulate the coarse spectro-temporal cues available with electric hearing; the degree of inter-aural mismatch was varied by adjusting the simulated insertion depth (SID) to be 25 mm (SID25), 22 mm (SID22) and 19 mm (SID19) from the base of the cochlea. Lateralization was measured using headphones and head-related transfer functions (HRTFs). Baseline lateralization was measured for unprocessed speech (UN) delivered to the left ear to simulate SSD and for binaural performance with the acoustic ear combined with the 16-channel vocoders (UN+SID25, UN+SID22 and UN+SID19). After completing baseline measurements, subjects completed six lateralization training exercises with the UN+SID22 condition, after which performance was re-measured for all baseline conditions. Post-training performance was significantly better than baseline for all conditions (

Indexed as

cochlear implantsinsertion depthlateralizationlocalizationsingle-sided deafness

Identifiers

PMID30065641
PMCPMC6056606

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.