Evidence map›Paper›PMID 30065274›Full record

ArticleScientific reports2018

Novel application of In Vivo Micro-Optical Coherence Tomography to assess Cornea scarring in an Animal Model.

Marcus Ang, Kavya Devarajan, Suchandrima Das, Gary H F Yam, Hla Mynt Htoon, Si Chen, Xinyu Liu, Linbo Liu, Michael Girard, Jodhbir S Mehta

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.5field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 7 citations in OpenAlex.

  1. Review
  2. Role of AS-OCT in Managing Corneal Disorders.Diagnostics (Basel, Switzerland) · 2022
    Review
  3. Frontiers in medicine · 2021
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 5 institutions in 1 country.

Marcus AngSingapore National Eye Centre, Singapore, Singapore. marcus.ang@snec.com.sg.
Kavya DevarajanSingapore Eye Research Institute, Singapore, Singapore.
Suchandrima DasSingapore Eye Research Institute, Singapore, Singapore.
Gary H F YamSingapore Eye Research Institute, Singapore, Singapore.
Hla Mynt HtoonSingapore Eye Research Institute, Singapore, Singapore.
Si ChenSchool of Electrical & Electronic Engineering and School of Chemical & Biomedical Engineering, Nanyang Technological University, Singapore, Singapore.
Xinyu LiuSchool of Electrical & Electronic Engineering and School of Chemical & Biomedical Engineering, Nanyang Technological University, Singapore, Singapore.
Linbo LiuSchool of Electrical & Electronic Engineering and School of Chemical & Biomedical Engineering, Nanyang Technological University, Singapore, Singapore.
Michael GirardSingapore Eye Research Institute, Singapore, Singapore.
Jodhbir S MehtaSingapore National Eye Centre, Singapore, Singapore.
Singapore Eye Research Institute · SGNanyang Technological University · SGDuke-NUS Medical School · SGNational University of Singapore · SGSingapore National Eye Center · SG

Funding

MOH | National Medical Research Council (NMRC) NMRC/CNIG/1128/2015National Research Foundation Singapore (National Research Foundation-Prime Minister's office, Republic of Singapore) NRF-CRP13-2014-05
6 · The paper itself

Abstract

This pilot study uses a micro-optical coherence tomography (micro-OCT) system with ~1 μm axial resolution specifically to image the cornea and corneal scars in vivo. We used an established murine corneal scar model by irregular phototherapeutic keratectomy in ten C57BL/6 mice, with serial imaging using the micro-OCT and compared to anterior segment (AS-OCT) (RTvue, Optovue, Fremont, CA) before and after scar induction. Main outcome was agreement between the AS-OCT and micro-OCT using Bland-Altman plots (95% limits of agreement, LoA).We analysed 10 control eyes and 10 eyes with corneal scars and found that there was good agreement between AS-OCT and micro-OCT (P > 0.05) LOA: lower limit -14 µm (95% CI: -19 to -8.8 µm) upper limit 23 µm (95% CI: 18 to 28.5 µm) in terms of central corneal thickness. There was also good agreement between AS-OCT and micro-OCT in terms of corneal scar measurements (P > 0.5; correlation coefficient >0.99) LOA lower limit -2.1 µm (95% CI: -2.8 to -1.5 µm); upper limit 1.8 µm (95% CI: 1.1 to 2.4 µm). Our pilot study suggests that this novel in vivo micro-OCT imaging technique was able to measure central corneal thickness and scar thickness in agreement with current AS-OCT techniques.

Indexed as

AnimalsCorneaCorneal InjuriesMiceMice, Inbred C57BLModels, AnimalPilot ProjectsTomography, Optical Coherence

Identifiers

PMID30065274
PMCPMC6068187
OpenAlexW2883647436

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.