Evidence map›Paper›PMID 30064849›Full record

ArticleUltrasound in medicine & biology2018

Real-Time in Vivo Photoacoustic Imaging in the Assessment of Myocardial Dynamics in Murine Model of Myocardial Ischemia.

Rashid Al Mukaddim, Allison Rodgers, Timothy A Hacker, Andrew Heinmiller, Tomy Varghese

Abstract read
In one paragraph

Article in Ultrasound in medicine & biology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
20citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

20 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Preclinical techniques to investigate exercise training in vascular pathophysiology.American journal of physiology. Heart and circulatory physiology · 2021
    Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Review
  14. Subaperture Processing-Based Adaptive Beamforming for Photoacoustic Imaging.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2021
    Article
  15. Article
  16. Spatiotemporal Coherence Weighting for In Vivo Cardiac Photoacoustic Image Beamformation.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2021
    Article
  17. Review
  18. Article
  19. Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Rashid Al MukaddimDepartment of Electrical and Computer Engineering, University of Wisconsin, Madison, Wisconsin, USA.
Allison RodgersSection of Cardiovascular Medicine, Department of Medicine, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA.
Timothy A HackerSection of Cardiovascular Medicine, Department of Medicine, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA.
Andrew HeinmillerFUJIFILM VisualSonics, Inc., Toronto, Ontario, Canada.
Tomy VargheseDepartment of Electrical and Computer Engineering, University of Wisconsin, Madison, Wisconsin, USA; Department of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA. Electronic address: tvarghese@wisc.edu.

Funding

UW COMPREHENSIVE CANCER CENTER SUPPORTP30CA014520 · NCI · UNIVERSITY OF WISCONSIN-MADISON · PI AMY TRENTHAM-DIETZ · 1985 to 2026
$142.6M
Real-time Ultrasonic Monitoring of Tumor AblationR01CA112192 · NCI · UNIVERSITY OF WISCONSIN-MADISON · PI VARGHESE, TOMY · 2007 to 2017
$2.6M
Ultrasonic and Photoacoustic Imaging System for Cancer & Cardiovascular ResearchS10OD018505 · OD · UNIVERSITY OF WISCONSIN-MADISON · PI VARGHESE, TOMY · 2015 to 2015
$908k
NCI NIH HHS P30 CA014520NCI NIH HHS R01 CA112192NIH HHS S10 OD018505
6 · The paper itself

Abstract

Photoacoustic imaging (PAI) is an evolving real-time imaging modality that combines the higher contrast of optical imaging with the higher spatial resolution of ultrasound imaging. We utilized dual-wavelength PAI for the diagnosis and monitoring of myocardial ischemia by assessing variations in blood oxygen saturation estimated in a murine model. The use of high-frequency ultrasound in conjunction with PAI enabled imaging of anatomic and functional changes associated with ischemia. Myocardial ischemia was established in eight mice by ligating the left anterior descending artery (LAD). Longitudinal results reveal that PAI is sensitive to acute myocardial ischemia, with a rapid decline in blood oxygen saturation (p ˂ 0.001) observed after LAD ligation (30 min: 33.05 ± 6.80%, 80 min: 36.59 ± 5.22%, 120 min: 36.70 ± 9.46%, 24 h: 40.55 ± 13.04%) compared with baseline (87.83 ± 5.73%). Variation in blood oxygen saturation was found to be linearly correlated with ejection fraction (%), fractional shortening (%) and stroke volume (µL), with Pearson's correlation coefficient values of 0.66, 0.67 and 0.77, respectively (p ˂ 0.001). Our results indicate that PAI has the potential for real-time diagnosis and monitoring of acute myocardial ischemia.

Indexed as

AnimalsDisease Models, AnimalHeartMaleMiceMice, Inbred BALB CMyocardial IschemiaPhotoacoustic TechniquesUltrasonographyHigh-frequency ultrasoundMurine modelMyocardial ischemiaPhotoacoustic imaging

Identifiers

PMID30064849
PMCPMC6135705

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.