Assessment of changes of regional ventilation distribution in the lung tissue depending on the driving pressure applied during high frequency jet ventilation.
Observational study in BMC anesthesiology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Assessment of Regional Lungs Aeration Changes Examined by Impedance Tomography, Depending on the Drive Pressure Applied During High Frequency Jet Ventilation.
Evaluation of the Double-Lumen Tube Vivasight-DL vs. Standard Duble-lumen Tube in Normal and Difficult Airway Scenarios: A Prospective, Randomized, Crossover, Simulation Trial
Who cites it
7 citing papers in PubMed, 12 citations in OpenAlex.
- A comparative study of conventional, High-flow, and jet ventilation via the Wei nasal jet tube for oxygen therapy in patients undergoing bronchoscopic intervention under deep sedation: a randomized controlled trial.Frontiers in medicine · 2026Trial
- High frequency jet ventilation through mask contributes to oxygen therapy among patients undergoing bronchoscopic intervention under deep sedation.BMC anesthesiology · 2021Trial
- Supraglottic jet oxygenation and ventilation for obese patients under intravenous anesthesia during hysteroscopy: a randomized controlled clinical trial.BMC anesthesiology · 2019Trial
- 3D Electrical Impedance Tomography of Regional Ventilation During Jet Ventilation: A Pilot Study.Laryngoscope investigative otolaryngology · 2026Article
- Predictive value of tidal volume and peak inspiratory pressure in normal frequency jet ventilation.Scientific reports · 2025Article
- Jet ventilation dynamics in rigid bronchoscope: insights from a simulated experimental model.BMC anesthesiology · 2025Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors at 3 institutions in 3 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundElectrical impedance tomography (EIT) is a tool to monitor regional ventilation distribution in patient's lungs under general anesthesia. The objective of this study was to assess the regional ventilation distribution using different driving pressures (DP) during high frequency jet ventilation (HFJV).
methodsProspective, observational, cross-over study. Patients undergoing rigid bronchoscopy were ventilated HFJV with DP 1.5 and 2.5 atm. Hemodynamic and ventilation parameters, as well as ventilation in different regions of the lungs in percentage of total ventilation, assessed by EIT, were recorded.
resultsThirty-six patients scheduled for elective rigid bronchoscopy. The final analysis included thirty patients. There was no significant difference in systolic, diastolic and mean arterial blood pressure, heart rate, and peripheral saturation between the two groups. Peak inspiratory pressure, mean inspiratory pressure, tidal volume, and minute volume significantly increased in the second, compared to the first intervention group. Furthermore, there were no statistically significant differences between each time profiles in all ROI regions in EIT.
conclusionsIn our study intraoperative EIT was an effective method of functional monitoring of the lungs during HFJV for rigid bronchoscopy procedure. Lower driving pressure was as effective in providing sufficient ventilation distribution through the lungs as the higher driving pressure but characterized by lower airway pressure.
trial registrationThe study was registered on ClinicalTrials.gov under no. NCT02997072 .