Evidence map›Paper›PMID 30064155›Full record

SynthesisThe Cochrane database of systematic reviews2018

Initial arch wires used in orthodontic treatment with fixed appliances.

Yan Wang, Chang Liu, Fan Jian, Grant T McIntyre, Declan T Millett, Joy Hickman, Wenli Lai

2 registry-linked trialsOpen access · greenAbstract readMeta-AnalysisSystematic Review
In one paragraph

Synthesis in The Cochrane database of systematic reviews, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 19 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
19citing papers in PubMed, 2 pooled it
3.3field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT05391542 nacompletednot on this mapstarted 2022, after this paper: background citation

Effectiveness of Tubular Coaxial Nickel-titanium and Copper Nickel-titanium Orthodontic Aligning Archwires: A Randomized Clinical Trial

TypeinterventionalSponsorUniversity of BaghdadRan2022 to 2022Enrolled33ConditionsAligning ArchwiresArmsaligning archwires
NCT05510206 nacompletednot on this mapstarted 2022, after this paper: background citation

The Effectiveness of SmartArch Versus Super Elastic Nickel-titanium Aligning Archwires: a Randomized Clinical Trial

TypeinterventionalSponsorUniversity of BaghdadRan2022 to 2022Enrolled40ConditionsCrowding of Anterior Mandibular TeethArmsLeveling and alignment
3 · Its place in the literature

Who cites it

19 citing papers in PubMed, 2 syntheses or guidelines pooled it, 49 citations in OpenAlex.

  1. Initial arch wires used in orthodontic treatment with fixed appliances.The Cochrane database of systematic reviews · 2024
    Pooled it
  2. Orthodontic treatment for crowded teeth in children.The Cochrane database of systematic reviews · 2021
    Pooled it
  3. Trial
  4. Trial
  5. Article
  6. Review
  7. Effect of Vitamin D on Orthodontic Tooth Movement.Journal of pharmacy & bioallied sciences · 2025
    Article
  8. Article
  9. Article
  10. Article
  11. Review
  12. Article
  13. Article
  14. Article
  15. Food Impaction in Dentistry: Revisited.Oral health & preventive dentistry · 2023
    Review
  16. Article
  17. Article
  18. Article
  19. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

7 authors at 5 institutions in 3 countries.

Yan WangDepartment of Orthodontics, State Key Laboratory of Oral Diseases, West China Hospital of Stomatology, Sichuan University, No. 14, Section Three, Ren Min Nan Road, Chengdu, Sichuan, China, 610041.
Chang Liu
Fan Jian
Grant T McIntyre
Declan T Millett
Joy Hickman
Wenli Lai
Sichuan University · CNCork University Hospital · IEGlan Clwyd Hospital · GBState Key Laboratory of Oral DiseasesUniversity of Dundee · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundInitial arch wires are the first arch wires to be inserted into the fixed appliance at the beginning of orthodontic treatment and are used mainly for the alignment of teeth by correcting crowding and rotations. With a number of different types of orthodontic arch wires available for initial tooth alignment, it is important to understand which wire is most efficient, as well as which wires cause least amount of root resorption and pain during the initial aligning stage of treatment. This is an update of the review entitledInitial arch wires for alignment of crooked teeth with fixed orthodontic braces, which was first published in 2010.

objectivesTo assess the effects of initial arch wires for the alignment of teeth with fixed orthodontic braces, in terms of the rate of tooth alignment, amount of root resorption accompanying tooth movement, and intensity of pain experienced by patients during the initial alignment stage of treatment. SEARCH

methodsCochrane Oral Health's Information Specialist searched the following databases: Cochrane Oral Health's Trials Register (to 5 October 2017), the Cochrane Central Register of Controlled Trials (CENTRAL) (the Cochrane Library, 2017, Issue 9), MEDLINE Ovid (1946 to 5 October 2017), and Embase Ovid (1980 to 5 October 2017. The US National Institutes of Health Trials Registry (ClinicalTrials.gov) and the World Health Organization International Clinical Trials Registry Platform were searched for ongoing trials. No restrictions were placed on the language or date of publication when searching the electronic databases. SELECTION CRITERIA: We included randomised controlled trials (RCTs) of initial arch wires to align teeth with fixed orthodontic braces. We included only studies involving participants with upper or lower, or both, full arch fixed orthodontic appliances. DATA COLLECTION AND ANALYSIS: Two review authors were responsible for study selection, 'Risk of bias' assessment and data extraction. We resolved disagreements by discussion between the review authors. We contacted corresponding authors of included studies to obtain missing information. We assessed the quality of the evidence for each comparison and outcome as high, moderate, low or very low, according to GRADE criteria. MAIN

resultsFor this update, we found three new RCTs (228 participants), bringing the total to 12 RCTs with 799 participants. We judged three studies to be at high risk of bias, and three to be at low risk of bias; six were unclear. None of the studies reported the adverse outcome of root resorption. The review assessed six comparisons.1. Multistrand stainless steel versus superelastic nickel-titanium (NiTi) arch wires. There were five studies in this group and it was appropriate to undertake a meta-analysis of two of them. There is insufficient evidence from these studies to determine whether there is a difference in rate of alignment between multistrand stainless steel and superelastic NiTi arch wires (mean difference (MD) -7.5 mm per month, 95% confidence interval (CI) -26.27 to 11.27; 1 study, 48 participants; low-quality evidence). The findings for pain at day 1 as measured on a 100 mm visual analogue scale suggested that there was no meaningful difference between the interventions (MD -2.68 mm, 95% CI -6.75 to 1.38; 2 studies, 127 participants; moderate-quality evidence).2. Multistrand stainless steel versus thermoelastic NiTi arch wires. There were two studies in this group, but it was not appropriate to undertake a meta-analysis of the data. There is insufficient evidence from the studies to determine whether there is a difference in rate of alignment between multistrand stainless steel and thermoelastic NiTi arch wires (low-quality evidence). Pain was not measured.3. Conventional NiTi versus superelastic NiTi arch wires. There were three studies in this group, but it was not appropriate to undertake a meta-analysis of the data. There is insufficient evidence from these studies to determine whether there is any difference between conventional and superelastic NiTi arch wires with regard to either alignment or pain (low- to very low-quality evidence).4. Conventional NiTi versus thermoelastic NiTi arch wires. There were two studies in this group, but it was not appropriate to undertake a meta-analysis of the data. There is insufficient evidence from these studies to determine whether there is a difference in alignment between conventional and thermoelastic NiTi arch wires (low-quality evidence). Pain was not measured.5. Single-strand superelastic NiTi versus coaxial superelastic NiTi arch wires. There was only one study (24 participants) in this group. There is moderate-quality evidence that coaxial superelastic NiTi can produce greater tooth movement over 12 weeks (MD -6.76 mm, 95% CI -7.98 to -5.55). Pain was not measured.6. Superelastic NiTi versus thermoelastic NiTi arch wires. There were three studies in this group, but it was not appropriate to undertake a meta-analysis of the data. There is insufficient evidence from these studies to determine whether there is a difference in alignment or pain between superelastic and thermoelastic NiTi arch wires (low-quality evidence). AUTHORS'

conclusionsModerate-quality evidence shows that arch wires of coaxial superelastic nickel-titanium (NiTi) can produce greater tooth movement over 12 weeks than arch wires made of single-strand superelastic NiTi. Moderate-quality evidence also suggests there may be no difference in pain at day 1 between multistrand stainless steel arch wires and superelastic NiTi arch wires. Other than these findings, there is insufficient evidence to determine whether any particular arch wire material is superior to any other in terms of alignment rate, time to alignment, pain and root resorption.

Indexed as

Dental AlloysAlloysHumansOrthodontic BracketsOrthodontic WiresRandomized Controlled Trials as TopicRoot ResorptionToothacheTooth Movement TechniquesAlloysDental Alloysnitinol

Identifiers

PMID30064155
PMCPMC6513532
OpenAlexW2887572082

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.