Evidence map›Paper›PMID 30063238›Full record

ArticleLab on a chip2018

A glass-based, continuously zonated and vascularized human liver acinus microphysiological system (vLAMPS) designed for experimental modeling of diseases and ADME/TOX.

Xiang Li, Subin M George, Lawrence Vernetti, Albert H Gough, D Lansing Taylor

Abstract read
In one paragraph

Article in Lab on a chip, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 76 papers.

0numbers the graph read from it
0cells of the map it votes in
76citing papers in PubMed
6.6field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

76 citing papers in PubMed, 138 citations in OpenAlex.

  1. Leveraging Microphysiological Systems to Facilitate Neutrophil-Based Cancer Immunotherapy.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Review
  2. Article
  3. Review
  4. Review
  5. Review
  6. Article
  7. Review
  8. Article
  9. Article
  10. Review
  11. Review
  12. Lessons Learned from Liver-on-Chip Platform.Annals of biomedical engineering · 2025
    Review
  13. Review
  14. Review
  15. Review
  16. Review
  17. Article
  18. Review
  19. Article
  20. Article

16 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Xiang LiDrug Discovery Institute, University of Pittsburgh, Pittsburgh, PA 15260, USA. dltaylor@pitt.edu.
Subin M George
Lawrence Vernetti
Albert H Gough
D Lansing Taylor
University of Pittsburgh · US

Funding

VECTOR CORE FACILITYP30CA047904 · NCI · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI Jessie Nedrow · 1988 to 2026
$158.0M
Measuring the Temporal-Spatial Responses of Dormancy and Drug Resistance in a Human Breast Cancer Metastatic Niche within a Liver-on-a-Chip Microphysiological PlatformUH3TR000503 · NCATS · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI TAYLOR, D. LANSING · 2014 to 2016
$6.2M
InCell 6000 High Content Instrument for Cellular Systems Biology ProgramS10OD012269 · OD · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI TAYLOR, D. LANSING · 2013 to 2013
$502k
NCATS NIH HHS UH3 TR000503NCI NIH HHS P30 CA047904NIH HHS S10 OD012269
6 · The paper itself

Abstract

The vLAMPS is a human, biomimetic liver MPS, in which the ECM and cell seeding of the intermediate layer prior to assembly, simplifies construction of the model and makes the platform user-friendly. This primarily glass microfluidic device is optimal for real-time imaging, while minimizing the binding of hydrophobic drugs/biologics to the materials that constitute the device. The assembly of the three layered device with primary human hepatocytes and liver sinusoidal endothelial cells (LSECs), and human cell lines for stellate and Kupffer cells, creates a vascular channel separated from the hepatic channel (chamber) by a porous membrane that allows communication between channels, recapitulating the 3D structure of the liver acinus. The vascular channel can be used to deliver drugs, immune cells, as well as various circulating cells and other factors to a stand-alone liver MPS and/or to couple the liver MPS to other organ MPS. We have successfully created continuous oxygen zonation by controlling the flow rates of media in the distinct vascular and hepatic channels and validated the computational modeling of zonation with oxygen sensitive and insensitive beads. This allows the direct investigation of the role of zonation in physiology, toxicology and disease progression. The vascular channel is lined with human LSECs, recapitulating partial immunologic functions within the liver sinusoid, including the activation of LSECs, promoting the binding of polymorphonuclear leukocytes (PMNs) followed by transmigration into the hepatic chamber. The vLAMPS is a valuable platform to investigate the functions of the healthy and diseased human liver using all primary human cell types and/or iPSC-derived cells.

Indexed as

GlassLab-On-A-Chip DevicesNeovascularization, PhysiologicAcinar CellsHumansLiverReactive Oxygen SpeciesTissue Array AnalysisReactive Oxygen Species

Identifiers

PMID30063238
PMCPMC6113686
OpenAlexW2887856756

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.