Evidence map›Paper›PMID 30062479›Full record

ArticleJournal of the American Society for Mass Spectrometry2018

Operation and Performance of a Mass-Selective Cryogenic Linear Ion Trap.

Larry F Tesler, Adam P Cismesia, Matthew R Bell, Laura S Bailey, Nicolas C Polfer

Abstract read
In one paragraph

Article in Journal of the American Society for Mass Spectrometry, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Larry F TeslerDepartment of Chemistry, University of Florida, P.O. Box 117200, Gainesville, FL, 32611-7200, USA.
Adam P CismesiaDepartment of Chemistry, University of Florida, P.O. Box 117200, Gainesville, FL, 32611-7200, USA.
Matthew R BellDepartment of Chemistry, University of Florida, P.O. Box 117200, Gainesville, FL, 32611-7200, USA.
Laura S BaileyDepartment of Chemistry, University of Florida, P.O. Box 117200, Gainesville, FL, 32611-7200, USA.
Nicolas C PolferDepartment of Chemistry, University of Florida, P.O. Box 117200, Gainesville, FL, 32611-7200, USA. polfer@chem.ufl.edu.ORCID http://orcid.org/0000-0002-5892-8667

Funding

Infrared laser spectroscopy of mass-separated metabolitesR01GM110077 · NIGMS · UNIVERSITY OF FLORIDA · PI ROITBERG, ADRIAN ENRIQUE · 2014 to 2017
$926k
Directorate for Mathematical and Physical Sciences CHE-1403262Foundation for the National Institutes of Health GM110077NIGMS NIH HHS R01 GM110077
6 · The paper itself

Abstract

We report on the performance of a cryogenic 2D linear ion trap (cryoLIT) that is shown to be mass-selective in the temperature range of 17-295 K. As the cryoLIT is cooled, the ejection voltages during the mass instability scan decrease, which results in an effective mass shift to lower m/z relative to room temperature. This is attributed to a decrease in trap radius caused by thermal contraction. Additionally, the cryoLIT generates reproducible mass spectra from day-to-day, and is capable of performing stored waveform inverse Fourier transform (SWIFT) mass isolation of fragile N

Indexed as

Cryogenic ion spectroscopyCryogenicsInfrared spectroscopyLinear ion trapTagging

Identifiers

PMID30062479
PMCPMC6301008

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.