Evidence map›Paper›PMID 30058147›Full record

ArticleMagnetic resonance in medicine2019

Dynamic off-resonance correction for spiral real-time MRI of speech.

Yongwan Lim, Sajan Goud Lingala, Shrikanth S Narayanan, Krishna S Nayak

Open access · bronzeAbstract read
In one paragraph

Article in Magnetic resonance in medicine, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed
3.2field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed, 25 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Real-Time Magnetic Resonance Imaging.Journal of magnetic resonance imaging : JMRI · 2022
    Review
  8. Aliasing artifact reduction in spiral real-time MRI.Magnetic resonance in medicine · 2021
    Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Improved real-time tagged MRI using REALTAG.Magnetic resonance in medicine · 2020
    Article
  15. Article
  16. Article
  17. Article
  18. 3D dynamic MRI of the vocal tract during natural speech.Magnetic resonance in medicine · 2019
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Yongwan LimMing Hsieh Department of Electrical Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California.
Sajan Goud LingalaMing Hsieh Department of Electrical Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California.
Shrikanth S NarayananMing Hsieh Department of Electrical Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California.
Krishna S NayakMing Hsieh Department of Electrical Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California.
University of Southern California · US

Funding

DYNAMICS OF VOCAL TRACT SHAPINGR01DC007124 · NIDCD · UNIVERSITY OF SOUTHERN CALIFORNIA · PI NARAYANAN, SHRIKANTH · 2005 to 2020
$6.1M
National Science Foundation 1514544NIDCD NIH HHS R01 DC007124NIH Clinical CenterNIH HHS R01DC007124
6 · The paper itself

Abstract

purposeTo improve the depiction and tracking of vocal tract articulators in spiral real-time MRI (RT-MRI) of speech production by estimating and correcting for dynamic changes in off-resonance.

methodsThe proposed method computes a dynamic field map from the phase of single-TE dynamic images after a coil phase compensation where complex coil sensitivity maps are estimated from the single-TE dynamic scan itself. This method is tested using simulations and in vivo data. The depiction of air-tissue boundaries is evaluated quantitatively using a sharpness metric and visual inspection.

resultsSimulations demonstrate that the proposed method provides robust off-resonance correction for spiral readout durations up to 5 ms at 1.5T. In -vivo experiments during human speech production demonstrate that image sharpness is improved in a majority of data sets at air-tissue boundaries including the upper lip, hard palate, soft palate, and tongue boundaries, whereas the lower lip shows little improvement in the edge sharpness after correction.

conclusionDynamic off-resonance correction is feasible from single-TE spiral RT-MRI data, and provides a practical performance improvement in articulator sharpness when applied to speech production imaging.

Indexed as

Magnetic Resonance ImagingSignal Processing, Computer-AssistedAlgorithmsComputer SimulationHealthy VolunteersHumansImage Processing, Computer-AssistedMouthPalate, SoftPharynxReproducibility of ResultsSpeechTongueoff-resonance correctionreal-time MRIspeech productionspiral

Identifiers

PMID30058147
PMCPMC6258270
OpenAlexW2885934375

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked