Evidence map›Paper›PMID 30058070›Full record

SynthesisThe Cochrane database of systematic reviews2018

Heparin versus 0.9% sodium chloride locking for prevention of occlusion in central venous catheters in adults.

Eduardo López-Briz, Vicente Ruiz Garcia, Juan B Cabello, Sylvia Bort-Martí, Rafael Carbonell Sanchis, Amanda Burls

Open access · bronzeAbstract readMeta-AnalysisSystematic Review
In one paragraph

Synthesis in The Cochrane database of systematic reviews, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 26 papers, 4 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
26citing papers in PubMed, 4 pooled it
10.3field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

26 citing papers in PubMed, 4 syntheses or guidelines pooled it, 66 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Pooled it
  4. Pooled it
  5. Trial
  6. Trial
  7. Article
  8. Review
  9. Review
  10. Review
  11. Article
  12. Article
  13. Article
  14. Article
  15. Canadian oncology nursing journal = Revue canadienne de nursing oncologique · 2022
    Article
  16. Article
  17. Article
  18. Article
  19. Review
  20. Brief Report on Double-Chamber Syringes Patents and Implications for Infusion Therapy Safety and Efficiency.International journal of environmental research and public health · 2020
    Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 2 countries.

Eduardo López-BrizDepartment of Pharmacy & CASP Spain, La Fe University Hospital, Avda Fernando Abril Martorell 106, Valencia, Valencia, Spain, 46026.
Vicente Ruiz Garcia
Juan B Cabello
Sylvia Bort-Martí
Rafael Carbonell Sanchis
Amanda Burls
Hospital Universitari i Politècnic La Fe · ESCity, University of London · GBHospital de Sagunto · ESHospital General Universitario de Alicante Doctor Balmis · ES

Funding

Chief Scientist Office ETM/442
6 · The paper itself

Abstract

backgroundIntermittent locking of central venous catheters (CVCs) is undertaken to help maintain their patency. There are systematic variations in care: some practitioners use heparin (at different concentrations), whilst others use 0.9% NaCl (normal saline). This review looks at the effectiveness and safety of intermittent locking with heparin compared to 0.9% NaCl to see if the evidence establishes whether one is better than the other. This work is an update of a review first published in 2014.

objectivesTo assess the effectiveness and safety of intermittent locking of CVCs with heparin versus normal saline (NS) in adults to prevent occlusion. SEARCH

methodsThe Cochrane Vascular Information Specialist (CIS) searched the Specialised Register (last searched 11 June 2018) and the Cochrane Central Register of Controlled Trials (CENTRAL; 2018, Issue 5). Searches were also carried out in MEDLINE, Embase, CINAHL, and clinical trials databases (11 June 2018). SELECTION CRITERIA: We included randomised controlled trials in adults ≥ 18 years of age with a CVC that compared intermittent locking with heparin at any concentration versus NS. We applied no restriction on language. DATA COLLECTION AND ANALYSIS: Two review authors independently selected trials, assessed quality, and extracted data. We contacted trial authors to retrieve additional information, when necessary. We carried out statistical analysis using Review Manager 5 and assessed the overall quality of the evidence supporting assessed outcomes using GRADE. We carried out prespecified subgroup analysis. MAIN

resultsWe identified five new studies for this update (six prior studies were included in the original review), bringing the number of eligible studies to 11, with a total of 2392 participants. We noted differences in methods used by the included studies and variation in heparin concentrations (10 to 5000 IU/mL), time to follow-up (1 to 251.8 days), and the unit of analysis used (participant, catheter, line access).Combined results from these studies showed fewer occlusions with heparin than with NS (risk ratio (RR) 0.70, 95% confidence interval (CI) 0.51 to 0.95; P = 0.02; 1672 participants; 1025 catheters from 10 studies; I² = 14%) and provided very low-quality evidence.We carried out subgroup analysis by unit of analysis (testing for subgroup differences (P = 0.23; I² = 30.3%). When the unit of analysis was the participant, results show no clear differences in all occlusions between heparin and NS (RR 0.79, 95% CI 0.58 to 1.08; P = 0.15; 1672 participants; seven studies). Subgroup analysis using the catheter as the unit of analysis shows fewer occlusions with heparin use (RR 0.53, 95% CI 0.29 to 0.95; P = 0.03; 1025 catheters; three studies). When the unit of analysis was line access, results show no clear differences in occlusions between heparin and NS (RR 1.08, 95% CI 0.84 to 1.40; 770 line accesses; one study).We found no clear differences in the duration of catheter patency (mean difference (MD) 0.44 days, 95% CI -0.10 to 0.99; P = 0.11; 1036 participants; 752 catheters; six studies; low-quality evidence).We found no clear evidence of a difference in the following: CVC-related sepsis (RR 0.74, 95% CI 0.03 to 19.54; P = 0.86; 1097 participants; two studies; low-quality evidence); mortality (RR 0.76, 95% CI 0.44 to 1.31; P = 0.33; 1100 participants; three studies; low-quality evidence); haemorrhage at any site (RR 1.32, 95% CI 0.57 to 3.07; P = 0.52; 1245 participants; four studies; moderate-quality evidence); or heparin-induced thrombocytopaenia (RR 0.21, 95% CI 0.01 to 4.27; P = 0.31; 443 participants; three studies; low-quality evidence).The main reasons for downgrading the quality of evidence were unclear allocation concealment, imprecision, and suspicion of publication bias. AUTHORS'

conclusionsGiven the very low quality of the evidence, we are uncertain whether intermittent locking with heparin results in fewer occlusions than intermittent locking with NS. Low-quality evidence suggests that heparin may have little or no effect on catheter patency. Although we found no evidence of differences in safety (sepsis, mortality, or haemorrhage), the combined trials are not powered to detect rare adverse events such as heparin-induced thrombocytopaenia.

Indexed as

Catheterization, Central VenousCatheter ObstructionCentral Venous CathetersAdultAnticoagulantsCatheter-Related InfectionsHemorrhageHeparinHumansSodium ChlorideTherapeutic IrrigationThrombocytopeniaAnticoagulantsHeparinSodium Chloride

Identifiers

PMID30058070
PMCPMC6513298
OpenAlexW2886277230

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked